The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Wireless bioresorbable electronic system enables sustained nonpharmacological neuroregenerative therapy
Abstract
Peripheral nerve injuries represent a significant problem in public health, constituting 2-5% of all trauma cases 1 . For severe nerve injuries, even advanced forms of clinical intervention often lead to incomplete and unsatisfactory motor and/or sensory function 2 . Numerous studies report the potential of pharmacological approaches (for example, growth factors, immunosuppressants) to accelerate and enhance nerve regeneration in rodent models 3-10 . Unfortunately, few have had a positive impact in clinical practice. Direct intraoperative electrical stimulation of injured nerve tissue proximal to the site of repair has been demonstrated to enhance and accelerate functional recovery 11,12 , suggesting a novel nonpharmacological, bioelectric form of therapy that could complement existing surgical approaches. A significant limitation of this technique is that existing protocols are constrained to intraoperative use and limited therapeutic benefits 13 . Herein we introduce (i) a platform for wireless, programmable electrical peripheral nerve stimulation, built with a collection of circuit elements and substrates that are entirely bioresorbable and biocompatible, and (ii) the first reported demonstration of enhanced neuroregeneration and functional recovery in rodent models as a result of multiple episodes of electrical stimulation of injured nervous tissue.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Utilizing a deposited layer of Mg embedded in insulting polymer to deliver electrical stimuli from the receiver antenna to the tissue, the system successfully enhanced neuroregeneration and functional recovery in rodent models (Figure 15F).[303]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [303]
Citations
Cites
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617
Natural-based plasticizers and biopolymer films: A review
Vieira, M. G. A., da Silva, M. A., dos Santos, L. O., & Beppu, M. M. (2011) · European Polymer Journal · doi:10.1016/j.eurpolymj.2010.12.011 · Cited by 1,992
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
Bioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
Self-citationNoble, J., Munro, C. A., Prasad, V. S. S. V., & Midha, R. (1998) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199807000-00025 · Cited by 995
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.004 · Cited by 814
Density and composition of mammalian muscle
Méndez, J., & Keys, A. (1960) · Metabolism · Cited by 802
Development of fibrin derivatives for controlled release of heparin-binding growth factors
Sakiyama-Elbert, S. E., & Hubbell, J. A. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00221-7 · Cited by 565
FIBER ARCHITECTURE AND MUSCLE FUNCTION
Gans, C. (1982) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-198201000-00006 · Cited by 491
Dissolvable Metals for Transient Electronics
Yin, L., Cheng, H., Mao, S., Haasch, R., Liu, Y., Xie, X., Hwang, S., Jain, H., Kang, S., Su, Y., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201301847 · Cited by 487
Self-citation
Research works printed but not linked: 1
- Winter, W. G., Schutt, R. C., Sisken, B. F. & Smith, S. D. Effects of low levels of direct current on peripheral nerve regeneration. Trans. Orthop. Res. Soc. 6, 304 (1981).
Cited by
Design of biodegradable, implantable devices towards clinical translation
Li, C., Guo, C., Fitzpatrick, V., Ibrahim, A., Zwierstra, M. J., Hanna, P., Lechtig, A., Nazarian, A., Lin, S. J., & Kaplan, D. L. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0150-z · Cited by 808
Electrical bioadhesive interface for bioelectronics
Deng, J., Yuk, H., Wu, J., Varela, C. E., Chen, X., Roche, E. T., Guo, C. F., & Zhao, X. (2021) · Nature Materials · doi:10.1038/s41563-020-00814-2 · Cited by 727
Multifunctional materials for implantable and wearable photonic healthcare devices
Lee, G.-H., Moon, H., Kim, H., Lee, G. H., Kwon, W., Yoo, S., Myung, D., Yun, S. H., Bao, Z., & Hahn, S. K. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0167-3 · Cited by 667
Topological supramolecular network enabled high-conductivity, stretchable organic bioelectronics
Jiang, Y., Zhang, Z., Wang, Y.-X., Li, D., Coen, C.-T., Hwaun, E., Chen, G., Wu, H.-C., Zhong, D., Niu, S., et al. (2022) · Science · doi:10.1126/science.abj7564 · Cited by 617
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Metadata
- Authors
- Koo, J., MacEwan, M. R., Kang, S.-K., Won, S. M., Stephen, M., Gamble, P., Xie, Z., Yan, Y., Chen, Y.-Y., Shin, J., Birenbaum, N., Chung, S., Kim, S. B., Khalifeh, J., Harburg, D. V., Bean, K., Paskett, M., Kim, J., Zohny, Z. S., Lee, S. M., Zhang, R., Luo, K., Ji, B., Banks, A., Lee, H. M., Huang, Y., Ray, W. Z., & Rogers, J. A.
- Affiliations
- Northwestern University (US)
- Washington University in St. Louis (US)
- Korea Advanced Institute of Science and Technology (KR)
- University of Illinois Urbana-Champaign (US)
- Kwangwoon University (KR)
- Corresponding author
- Ray, Wilson Z.
- Rogers, John A.
- ORCID
- Venue
- Nature Medicine
- Published
- 2018-10-08
- Volume
- 24
- Issue
- 12
- Pages
- 1830-1836
- ISSN
- 1078-8956 (ISSN-L)
- 1546-170X
- OpenAlex
- W2895321679
- Semantic Scholar
- 3206c70eed25bc433cf39f22ff2cc137874feb87
- Cited by
- 496
- References
- 49
- Citations by year
- 2026: 41 · 2025: 69 · 2024: 77 · 2023: 69 · 2022: 63 · 2021: 81 · 2020: 62 · 2019: 33 · 2018: 1
- FWCI
- 20.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- peripheral nerve injury, peripheral nerve regeneration, electrical nerve stimulation, functional recovery, rodent models
- MeSH terms
- Electric Stimulation, Humans, Nerve Regeneration, Wound Healing, Recovery of Function, Absorbable Implants, Wireless Technology, Peripheral Nerve Injuries
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wireless bioresorbable electronic system enables sustained nonpharmacological neuroregenerative therapy. https://app.cochat.ai/papers/10.1038/s41591-018-0196-2
- The paper
- Koo, J., MacEwan, M. R., Kang, S.-K., Won, S. M., Stephen, M., Gamble, P., Xie, Z., Yan, Y., Chen, Y.-Y., Shin, J., Birenbaum, N., Chung, S., Kim, S. B., Khalifeh, J., Harburg, D. V., Bean, K., Paskett, M., Kim, J., Zohny, Z. S., . . . Rogers, J. A. (2018). Wireless bioresorbable electronic system enables sustained nonpharmacological neuroregenerative therapy. Nature Medicine. https://doi.org/10.1038/s41591-018-0196-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.