The DOI matches its Crossref record.
Doppler color flow imaging
Abstract
By simultaneous processing of frequency, phase, and amplitude information in the backscattered ultrasound signal, new instruments now permit the realtime display of high‐resolution grey scale images of tissue combined with the simultaneous display of flow data from vessels within the scan plane. Doppler Color Flow Imaging, or DCFI, using such processing, permits blood flow direction and relative velocity to be detected and displayed in a color encoded display from throughout the ultrasound image. We have tested a new Doppler color flow imaging system over a period of two years to evaluate the carotid arteries, peripheral arteries and veins, and dialysis fistulas. In the abdomen and pelvis we have imaged blood flow to the liver, spleen, kidneys, uterus and renal transplants. Our experience in over 500 patients leads us to conclude that DCFI has significant advantages over conventional duplex Doppler sonography for blood flow evaluation. For examination of carotid and peripheral vessels, we have found DCFI to permit more rapid assessment in both normal and abnormal states. Areas of vessel narrowing or turbulent flow may be identified rapidly and accurately, and vessel orientation may be determined precisely, allowing accurate calculation of blood flow velocity from Doppler frequency shifts. The system we have used has adequate penetration and sensitivity to allow imaging of hepatic and renal blood flow and is extremely promising as a method of imaging organ perfusion and in the detection of abnormalities of perfusion that accompany disease, such as transplant rejection. Tumor vascularity may also be identified with DCFI, opening the possibilty of additional clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Transcranial color-coded real-time sonography in adults.
Bogdahn, U., Becker, G., Winkler, J., Greiner, K., Perez, J., & Meurers, B. (1990) · Stroke · doi:10.1161/01.str.21.12.1680 · Cited by 279
Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00763-4 · Cited by 274
Metadata
- Authors
- Merritt, C. R. B.
- Venue
- Journal of Clinical Ultrasound
- Publisher
- Wiley
- Published
- 1987-11
- Volume
- 15
- Issue
- 9
- Pages
- 591-597
- ISSN
- 0091-2751 (ISSN-L)
- 1097-0096
- OpenAlex
- W2072642525
- Cited by
- 237
- References
- 0
- FWCI
- 16.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Doppler color flow imaging. https://app.cochat.ai/papers/10.1002/jcu.1870150904
- The paper
- Merritt, C. R. B. (1987). Doppler color flow imaging. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.1870150904
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.