Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
The DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
Stretchable wearable devices for the continuous monitoring of physiological signals from deep tissues are constrained by the depth of signal penetration and by difficulties in resolving signals from specific tissues. Here, we report the development and testing of a prototype skin-conformal ultrasonic phased array for the monitoring of haemodynamic signals from tissues up to 14 cm beneath the skin. The device allows for active focusing and steering of ultrasound beams over a range of incident angles so as to target regions of interest. In healthy volunteers, we show that the phased array can be used to monitor Doppler spectra from cardiac tissues, record central blood flow waveforms and estimate cerebral blood supply in real time. Stretchable and conformal skin-worn ultrasonic phased arrays may open up opportunities for wearable diagnostics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Other mechanisms of flexible health monitoring in rehabilitation, like optoelectronic[263,264] and ultrasound[265,266] devices, can also be applied to heartbeat, pulse oximetry, blood pressure, and other on-body measurements.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [265]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Materials and Mechanics for Stretchable Electronics
Rogers, J. A., Someya, T., & Huang, Y. (2010) · Science · doi:10.1126/science.1182383 · Cited by 5,042
Self-citationWearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Ommen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Prognosis in Acute Organ-System Failure
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Annals of Surgery · doi:10.1097/00000658-198512000-00004 · Cited by 1,225
The Assessment of Endothelial Function: From Research Into Clinical Practice
Flammer, A. J., Anderson, T., Celermajer, D. S., Creager, M. A., Deanfield, J., Ganz, P., Hamburg, N. M., Lüscher, T. F., Shechter, M., Taddei, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.093245 · Cited by 1,153
Speckle in ultrasound B-mode scans
Burckhardt, C. B. (1978) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1978.30978 · Cited by 1,066
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Research works printed but not linked: 1
- J. Lee, H.-S. & Sodini, C. G. in Intracranial Pressure & Neuromonitoring XVI 111–114 (Springer, 2018).
Cited by
A wearable cardiac ultrasound imager
Hu, H., Huang, H., Li, M., Gao, X., Yin, L., Qi, R., Wu, R. S., Chen, X., Ma, Y., Shi, K., et al. (2023) · Nature · doi:10.1038/s41586-022-05498-z · Cited by 644
Self-citationBioadhesive ultrasound for long-term continuous imaging of diverse organs
Wang, C., Chen, X., Wang, L., Makihata, M., Liu, H.-C., Zhou, T., & Zhao, X. (2022) · Science · doi:10.1126/science.abo2542 · Cited by 599
“Other wearable ultrasound imaging devices (12, 14-18) did not report their lateral resolutions.”
BackgroundInfluentialSelf-citationFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
A three-dimensional liquid diode for soft, integrated permeable electronics
Zhang, B., Li, J., Zhou, J., Chow, L., Zhao, G., Huang, Y., Ma, Z., Zhang, Q., Yang, Y., Yiu, C. K., et al. (2024) · Nature · doi:10.1038/s41586-024-07161-1 · Cited by 417
Self-citationA fully integrated wearable ultrasound system to monitor deep tissues in moving subjects
Lin, M., Zhang, Z., Gao, X., Bian, Y., Wu, R. S., Park, G., Lou, Z., Zhang, Z., Xu, X., Chen, X., et al. (2024) · Nature Biotechnology · doi:10.1038/s41587-023-01800-0 · Cited by 364
“…in response to stressors can benefit a broad range of populations, from athletes who need training optimization, to cardiac rehabilitation patients who require safety measures, and to general high-risk populations for cardiovascular risk stratification and prediction (Supplementary Discussion 19).”
InfluentialSelf-citation
Metadata
- Authors
- Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., Chen, Y., Lei, Y., Lee, T., Chien, S., Jang, K.-I., Kistler, E. B., & Xu, S.
- Affiliations
- Harvard University (US)
- University of California San Diego (US)
- Yonsei University (KR)
- Daegu Gyeongbuk Institute of Science and Technology (KR)
- Corresponding author
- Xu, Sheng
- ORCID
- Venue
- Nature Biomedical Engineering
- Published
- 2021-07-16
- Volume
- 5
- Issue
- 7
- Pages
- 749-758
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3177774876
- Semantic Scholar
- c362c08ae1bf66f78c06e49aa3c46c3ecc0a23fa
- Cited by
- 274
- References
- 76
- Citations by year
- 2026: 42 · 2025: 78 · 2024: 62 · 2023: 51 · 2022: 34 · 2021: 7
- FWCI
- 11.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r21eb027303-02)
- National Institute of Biomedical Imaging and Bioengineering (R21 EB027303)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- wearable diagnostics, Doppler ultrasound, cerebral blood flow
- MeSH terms
- Wearable Electronic Devices, Cerebrovascular Circulation, Heart, Hemodynamics, Humans, Monitoring, Physiologic, Ultrasonography, Doppler, Microarray Analysis, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays. https://app.cochat.ai/papers/10.1038/s41551-021-00763-4
- The paper
- Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., Chen, Y., Lei, Y., Lee, T., Chien, S., Jang, K.-I., Kistler, E. B., & Xu, S. (2021). Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays. Nature Biomedical Engineering. https://doi.org/10.1038/s41551-021-00763-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.