Diagnostic accuracy of hepatorenal index in the detection and grading of hepatic steatosis
The DOI matches its Crossref record.
Abstract
Purpose: The objectives of our study were to assess the accuracy of hepatorenal index (HRI) in detection and grading of hepatic steatosis and to evaluate various factors that can affect the HRI measurement. Methods: Forty‐five patients, who had undergone an abdominal sonographic examination within 30 days of liver biopsy, were enrolled. The HRI was calculated as the ratio of the mean brightness levels of the liver and renal parenchymas. The effect of the measurement technique on the HRI was evaluated by using various sizes, depths, and locations of the regions of interest (ROIs) in the liver. The measurements were obtained by two observers. The HRI was compared with the subjective grading of steatosis. Results: The optimal HRI cutoff to detect steatosis was 2.01, yielding a sensitivity of 62.5% and specificity of 95.2%. Subjective grading had a sensitivity of 87.5% and specificity of 62.5%. HRIs of the hepatic steatosis group were statistically different from the no‐steatosis group (p < 0.05). However, there was no statistically significant difference between mild steatosis and no‐steatosis groups (p value = 0.72). There was a strong correlation between different HRIs based on variable placements of ROIs, except when the ROIs were positioned randomly. Interclass correlation coefficient for measurements performed by two observers was 0.74 (confidence interval: 0.58–0.86). Conclusions: The HRI is an effective tool for detecting hepatic steatosis. It provides similar accuracy for different methods of ROI placement (except for random placement) and has good interobserver agreement. It, however, is unable to effectively differentiate between absent and mild steatosis. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 44:580–586, 2016
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Byra, M., Styczynski, G., Szmigielski, C., Kalinowski, P., Michałowski, Ł., Paluszkiewicz, R., Ziarkiewicz-Wróblewska, B., Zieniewicz, K., Sobieraj, P., & Nowicki, A. (2018) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-018-1843-2 · Cited by 294
Machine learning for medical ultrasound: status, methods, and future opportunities
Brattain, L. J., Telfer, B. A., Dhyani, M., Grajo, J. R., & Samir, A. E. (2018) · Abdominal Radiology · doi:10.1007/s00261-018-1517-0 · Cited by 262
Pirmoazen, A. M., Khurana, A., El Kaffas, A., & Kamaya, A. (2020) · Theranostics · doi:10.7150/thno.40249 · Cited by 165
Jang, W., & Song, J. S. (2023) · Diagnostics · doi:10.3390/diagnostics13111852 · Cited by 55
Metadata
- Authors
- Chauhan, A., Sultan, L. R., Furth, E. E., Jones, L. P., Khungar, V., & Sehgal, C. M.
- Venue
- Journal of Clinical Ultrasound
- Publisher
- Wiley
- Published
- 2016-07-22
- Volume
- 44
- Issue
- 9
- Pages
- 580-586
- ISSN
- 0091-2751 (ISSN-L)
- 1097-0096
- OpenAlex
- W2500098445
- Cited by
- 76
- References
- 0
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic accuracy of hepatorenal index in the detection and grading of hepatic steatosis. https://app.cochat.ai/papers/10.1002/jcu.22382
- The paper
- Chauhan, A., Sultan, L. R., Furth, E. E., Jones, L. P., Khungar, V., & Sehgal, C. M. (2016). Diagnostic accuracy of hepatorenal index in the detection and grading of hepatic steatosis. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.22382
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.