The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Diagnostic value of combined pelvic floor ultrasound parameters for pelvic floor dysfunction and risk factors
Abstract
Objective: To investigate the diagnostic value of pelvic floor ultrasound parameters in combination for pelvic floor dysfunction (PFD), and to explore the risk factors. Methods: Forty PFD patients treated from April2019to December 2020(case group) and another 40 healthy women (control group) were enrolled. Their clinical data were collected, and both groups received three‐dimensional (3D) ultrasound of the pelvic floor. The diagnostic value of pelvic floor ultrasound parameters for PFD was assessed by receiver operating characteristic (ROC) curves. The risk factors of PFD were evaluated by multivariate logistic regression analysis. Results: The area under the ROC curve (AUC), sensitivity, and specificity of the parameters in combination for predicting PFD were 0.851 [95% confidence interval (CI): 0.743–0.959], 0.901, and 0.812, respectively, indicating acceptable accuracy. Results of logistic regression analysis revealed that spontaneous delivery, lateral episiotomy/laceration, and large bladder neck rotation angle, posterior urethrovesical angle (PUA), bladder neck tilt angle, bladder neck distance (BND), levator hiatus area (LHA) (at anal contraction), R‐LHA and V‐LHA were risk factors for PFD (p < 0.05), while physical exercise was a protective factor (p < 0.05). ROC curve analysis revealed that the AUC, sensitivity, and specificity of the forest map model were 0.822 (95% CI: 0.759–0.885), 0.942, and 0.601, respectively, indicating acceptable accuracy of the model. Internal data validation of the model demonstrated consistence of the predicted occurrence of PFD with the actual one. Conclusions: Spontaneous delivery, lateral episiotomy/laceration, and large bladder neck rotation angle, PUA, bladder neck tilt angle, BND, LHA (at anal contraction), R‐LHA and V‐LHA were risk factors for PFD.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Besides, the levator hiatus, which was found to be the missing link between LAM avulsion and pelvic organ prolapse,13 was also the principal etiological factor in the development of PFD.14”
From Association Between Mode of Delivery and Levator Ani Muscle Abnormalities on 4D Transperineal Ultrasound at 6 Weeks Postpartum (2026) · cites this paper as [14]
Citations
Cites
The effect of the first vaginal birth on pelvic floor anatomy and dysfunction
Urbankova, I., Grohregin, K., Hanacek, J., Krcmar, M., Feyereisl, J., Deprest, J., & Krofta, L. (2019) · International Urogynecology Journal · doi:10.1007/s00192-019-04044-2 · Cited by 99
Research works printed but not linked: 15
- 10.1007/s00192-020-04588-8 · DOI
- 10.1007/s00261-012-9870-x · DOI
- 10.1111/ggi.13618 · DOI
- 10.1007/s00192-019-03963-4 · DOI
- 10.1038/s41598-020-78625-3 · DOI
- 10.1007/s00192-017-3536-8 · DOI
- 10.1016/j.maturitas.2020.08.009 · DOI
- 10.1007/s00192-016-3123-4 · DOI · Paper page
- 10.1016/j.tjog.2014.08.001 · DOI
- 10.1016/j.ajog.2019.08.003 · DOI
- 10.21037/apm-20-784 · DOI
- 10.1016/0002-9378(80)90046-0 · DOI
- 10.1055/a-1109-2493 · DOI
- 10.1016/j.tjog.2020.05.014 · DOI
- 10.1007/s00192-021-04982-w · DOI
Cited by
Yi, J., Tang, Z., Wang, L., Zhang, B., Chen, X., & Liu, X. (2026) · International Journal of Women's Health · doi:10.2147/ijwh.s601021
“10 Besides, the levator hiatus, which was found to be the missing link between LAM avulsion and pelvic organ prolapse, 13 was also the principal etiological factor in the development of PFD. 14 Collectively, these findings establish the importance of vaginal birth in the occurrence of PDF.”
InfluentialSelf-citation
Metadata
- Authors
- Lin, C., Huang, W., Li, X., Wang, L., Yan, F., Zhou, X., Jiang, W., & Zhao, Y.
- Affiliations
- Third Department of Ultrasound Hengshui People's Hospital Hengshui China
- Department of Gynecology Zhuji People's Hospital Zhuji China
- Medical Department The Fifth People's Hospital of Hengshui Hengshui China
- Venue
- Journal of Clinical Ultrasound
- Publisher
- Wiley
- Published
- 2022-12-04
- Volume
- 51
- Issue
- 3
- Pages
- 465-471
- ISSN
- 0091-2751 (ISSN-L)
- 1097-0096
- OpenAlex
- W4310709860
- Cited by
- 11
- References
- 1
- Citations by year
- 2026: 4 · 2024: 6 · 2023: 1
- FWCI
- 1.28
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Clinical Ultrasound (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Urology › Pelvic floor disorders treatments
- Health Sciences › Medicine › Urology › Urinary Bladder and Prostate Research
- Health Sciences › Medicine › Psychiatry and Mental health › Sexual function and dysfunction studies
- Keywords
- pelvic floor dysfunction, pelvic floor ultrasound, 3D ultrasound, diagnostic accuracy, risk factors, spontaneous delivery, episiotomy, physical activity
- MeSH terms
- Anal Canal, Urinary Bladder, Female, Humans, Risk Factors, Ultrasonography, Pelvic Floor, Lacerations
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic value of combined pelvic floor ultrasound parameters for pelvic floor dysfunction and risk factors. https://app.cochat.ai/papers/10.1002/jcu.23397
- The paper
- Lin, C., Huang, W., Li, X., Wang, L., Yan, F., Zhou, X., Jiang, W., & Zhao, Y. (2023). Diagnostic value of combined pelvic floor ultrasound parameters for pelvic floor dysfunction and risk factors. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.23397