Controlled environment vitrification system: An improved sample preparation technique

Bellare, J. R., Davis, H. T., Scriven, L. E., Talmon, Y.·1988·Journal of Electron Microscopy Technique

Abstract

The controlled environment vitrification system (CEVS) permits cryofixation of hydrated biological and colloidal dispersions and aggregates from a temperature‐ and saturation‐controlled environment. Otherwise, specimens prepared in an uncontrolled laboratory atmosphere are subject to evaporation and heat transfer, which may introduce artifacts caused by concentration, pH, ionic strength, and temperature changes. Moreover, it is difficult to fix and examine the microstructure of systems at temperatures other than ambient (e.g., biological systems at in vivo conditions and colloidal systems above room temperature). A system has been developed that ensures that a liquid or partially liquid specimen is maintained in its original state while it is being prepared before vitrification and, once prepared, is vitrified with little alteration of its microstructure. A controlled environment is provided within a chamber where temperature and chemical activity of volatile components can be controlled while the specimen is being prepared. The specimen grid is mounted on a plunger, and a synchronous shutter is opened almost simultaneously with the release of the plunger, so that the specimen is propelled abruptly through the shutter opening into a cryogenic bath. We describe the system and its use and illustrate the value of the technique with TEM micrographs of surfactant microstructures in which specimen preparation artifacts were avoided. We also discuss applications to other instruments like SEM, to other techniques like freeze‐fracture, and to novel “on the grid” experiments that make it possible to freeze successive instants of dynamic processes such as membrane fusion, chemical reactions, and phase transitions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jemt.1060100111

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 614

Metadata

Authors
Bellare, J. R., Davis, H. T., Scriven, L. E., & Talmon, Y.
Venue
Journal of Electron Microscopy Technique
Publisher
Wiley
Published
1988-09
Volume
10
Issue
1
Pages
87-111
ISSN
  • 0741-0581 (ISSN-L)
  • 1553-0817
OpenAlex
W2057901960
Cited by
614
References
11
FWCI
8.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Controlled environment vitrification system: An improved sample preparation technique. https://app.cochat.ai/papers/10.1002/jemt.1060100111
The paper
Bellare, J. R., Davis, H. T., Scriven, L. E., & Talmon, Y. (1988). Controlled environment vitrification system: An improved sample preparation technique. Journal of Electron Microscopy Technique. https://doi.org/10.1002/jemt.1060100111

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.