The DOI matches its Crossref record.
Permeability of the blood‐brain barrier induced by 915 MHz electromagnetic radiation, continuous wave and modulated at 8, 16, 50, and 200 Hz
Abstract
Biological effects of electromagnetic fields (EMF) on the blood‐brain barrier (BBB) can be studied in sensitive and specific models. In a previous investigation of the permeability of the blood‐brain barrier after exposure to the various EMF‐components of proton magnetic resonance imaging (MRI), we found that the exposure to MRI induced leakage of Evans Blue labeled proteins normally not passing the BBB of rats [Salford et al. (1992), in: Resonance Phenomena in Biology, Oxford University Press, pp. 87–91]. In the present investigation we exposed male and female Fischer 344 rats in a transverse electromagnetic transmission line chamber to microwaves of 915 MHz as continuous wave (CW) and pulse‐modulated with repetition rates of 8, 16, 50, and 200 s−1. The specific energy absorption rate (SAR) varied between 0.016 and 5 W/kg. The rats were not anesthetized during the 2‐hour exposure. All animals were sacrificed by perfusion‐fixation of the brains under chloral hydrate anesthesia about 1 hour after the exposure. The brains were perfused with saline for 3–4 minutes, and thereafter fixed in 4% formaldehyde for 5–6 minutes. Central coronal sections of the brains were dehydrated and embedded in paraffin and sectioned at 5 μm. Albumin and fibrinogen were demonstrated immunohistochemically. The results show albumin leakage in 5 of 62 of the controls and in 56 of 184 of the animals exposed to 915 MHz microwaves. Continuous wave resulted in 14 positive findings of 35, which differ significantly from the controls (P = 0.002). With pulsed 915 MHz microwaves with repetition rates of 200, 50, 16, and 8 s−1, 42 of 149 were positive, which is highly significant at the P = 0.001 level. This reveals that both CW and pulsed 915 MHz microwaves have the potential to open up the BBB for albumin passage. However, there is no significant difference between continuous and pulsed 915 MHz microwaves in this respect. The frequency of occurrence of extravasates (26%) was found to be independent of SAR for SAR < 2.5 W/kg, but rose significantly for the higher SAR values (to 43%). The question of whether the opening of the blood‐brain barrier constitutes a health hazard demands further investigation. © 1994 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Overcoming the Blood–Brain Barrier: The Role of Nanomaterials in Treating Neurological Diseases
Furtado, D., Björnmalm, M., Ayton, S., Bush, A. I., Kempe, K., & Caruso, F. (2018) · Advanced Materials · doi:10.1002/adma.201801362 · Cited by 708
Leszczynski, D., Joenväärä, S., Reivinen, J., & Kuokka, R. (2002) · Differentiation · doi:10.1046/j.1432-0436.2002.700207.x · Cited by 408
Low-level exposure to radiofrequency electromagnetic fields: Health effects and research needs
Repacholi, M. H. (1998) · Bioelectromagnetics · doi:10.1002/(sici)1521-186x(1998)19:1<1::aid-bem1>3.0.co;2-5 · Cited by 357
Metadata
- Authors
- Salford, L. G., Brun, A., Sturesson, K., Eberhardt, J. L., & Persson, B. R. R.
- Venue
- Microscopy Research and Technique
- Publisher
- Wiley
- Published
- 1994-04-15
- Volume
- 27
- Issue
- 6
- Pages
- 535-542
- ISSN
- 1059-910X (ISSN-L)
- 1097-0029
- OpenAlex
- W2070337028
- Cited by
- 210
- References
- 0
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Permeability of the blood‐brain barrier induced by 915 MHz electromagnetic radiation, continuous wave and modulated at 8, 16, 50, and 200 Hz. https://app.cochat.ai/papers/10.1002/jemt.1070270608
- The paper
- Salford, L. G., Brun, A., Sturesson, K., Eberhardt, J. L., & Persson, B. R. R. (1994). Permeability of the blood‐brain barrier induced by 915 MHz electromagnetic radiation, continuous wave and modulated at 8, 16, 50, and 200 Hz. Microscopy Research and Technique. https://doi.org/10.1002/jemt.1070270608
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.