The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Multispectral fluorescence lifetime imaging by TCSPC
Abstract
We present a fluorescence lifetime imaging technique with simultaneous spectral and temporal resolution. The technique is fully compatible with the commonly used multiphoton microscopes and nondescanned (direct) detection. An image of the back‐aperture of the microscope lens is projected on the input of a fiber bundle. The input of the fiber bundle is circular, and the output is flattened to match the input slit of a spectrograph. The spectrum at the output of the spectrograph is projected on a 16‐anode PMT module. For each detected photon, the encoding logics of the PMT module deliver a timing pulse and the number of the PMT channel in which the photon was detected. The photons are accumulated by a multidimensional time‐correlated single photon counting (TCSPC) process. The recording process builds up a four‐dimensional photon distribution over the times of the photons in the excitation pulse period, the wavelengths of the photons, and the coordinates of the scan area. The method delivers a near‐ideal counting efficiency and is capable of resolving double‐exponential decay functions. We demonstrate the performance of the technique for autofluorescence imaging of tissue. Microsc. Res. Tech., 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly Nonlinear Photodamage in Two-Photon Fluorescence Microscopy
Hopt, A., & Neher, E. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76173-5 · Cited by 442
Cited by
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Self-citationBiological detection by optical oxygen sensing
Papkovsky, D. B., & Dmitriev, R. I. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60131e · Cited by 444
Fluorescence lifetime imaging microscopy in life sciences
Borst, J. W., & Visser, A. J. W. G. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/10/102002 · Cited by 168
Fluorescence Lifetime Imaging Microscopy for Quantitative Biological Imaging
Chen, L.-C., Lloyd, W. R., Chang, C.-W., Sud, D., & Mycek, M.-A. (2013) · Methods in Cell Biology · doi:10.1016/b978-0-12-407761-4.00020-8 · Cited by 55
Metadata
- Authors
- Becker, W., Bergmann, A., & Biskup, C.
- Venue
- Microscopy Research and Technique
- Publisher
- Wiley
- Published
- 2007-03-28
- Volume
- 70
- Issue
- 5
- Pages
- 403-409
- ISSN
- 1059-910X (ISSN-L)
- 1097-0029
- OpenAlex
- W1992489841
- Cited by
- 159
- References
- 1
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multispectral fluorescence lifetime imaging by TCSPC. https://app.cochat.ai/papers/10.1002/jemt.20432
- The paper
- Becker, W., Bergmann, A., & Biskup, C. (2007). Multispectral fluorescence lifetime imaging by TCSPC. Microscopy Research and Technique. https://doi.org/10.1002/jemt.20432
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.