The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Practical considerations in the use of polarized light microscopy in the analysis of the collagen network in articular cartilage
Abstract
Polarized light microscopy is a traditional method for visualizing the collagen network architecture of articular cartilage. Articular cartilage repair and tissue engineering studies have raised new demands for techniques capable of quantitative characterization of the scar and repair tissues, including properties of the collagen network. Modern polarized light microscopy can be used to measure collagen fibril orientation, parallelism, and birefringence. New commercial instruments are computer controlled and the measurements are easy to perform. However, often the interpretation of results causes difficulties, even errors, because the theoretical aspects of the technique are demanding. The aim of this study was to describe the instrumentation and properties of a modern polarized light microscope, to point out some sources of error in the interpretation of the results, and to recall the theoretical background of the polarized light microscopy. Microsc. Res. Tech., 2008. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The structure and transparency of the cornea
Maurice, D. M. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005758 · Cited by 1,129 · cited 1×
“Form and instrinsic birefringence can be calculated by performing series of measurements with variable liquids that possess different refractive indices (Maurice, 1957; Naylor, 1953; Speer and Dahners, 1979; Yarker et al., 1983).”
Background
Cited by
Rezakhaniha, R., Agianniotis, A., Schrauwen, J. T. C., Griffa, A., Sage, D., Bouten, C. V. C., van de Vosse, F. N., Unser, M., & Stergiopulos, N. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0325-z · Cited by 1,096
Polarized light interaction with tissues
Tuchin, V. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071114 · Cited by 384
Articular Cartilage: Structure and Regeneration
Becerra, J., Andrades, J. A., Guerado, E., Zamora-Navas, P., López-Puertas, J. M., & Reddi, A. H. (2010) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0191 · Cited by 268
Saarakkala, S., Julkunen, P., Kiviranta, P., Mäkitalo, J., Jurvelin, J. S., & Korhonen, R. K. (2010) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2009.08.003 · Cited by 252
Self-citation
Metadata
- Authors
- Rieppo, J., Hallikainen, J., Jurvelin, J. S., Kiviranta, I., Helminen, H. J., & Hyttinen, M. M.
- Venue
- Microscopy Research and Technique
- Publisher
- Wiley
- Published
- 2007-12-10
- Volume
- 71
- Issue
- 4
- Pages
- 279-287
- ISSN
- 1059-910X (ISSN-L)
- 1097-0029
- OpenAlex
- W2030610672
- Cited by
- 192
- References
- 1
- FWCI
- 5.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.