CoChat

Economized large‐scale production of high yield of rAAV for gene therapy applications exploiting baculovirus expression system

Negrete, Alejandro, Yang, Linda C., Mendez, Andres F., Levy, Justin R., Kotin, Robert M. · 2007 · The Journal of Gene Medicine
Cited by 54

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: The versatility of recombinant adeno‐associated vector (rAAV) as a gene delivery system is due to the vector's ability to transduce different cell types as well as dividing and non‐dividing cells. Large‐scale production of rAAV remains one of the major challenges for continued development of pre‐clinical and clinical studies, and for its potential commercialization. The baculovirus expression vectors (BEVS) and insect cells represent a potential method to produce rAAV economically at large scale. This technology uses three different BEV s (Bac‐Rep, Bac‐GFP, and Bac‐VP) each at a multiplicity of infection (MOI) of 3. We reported previously the production of rAAV at 40 L scale using a stirred‐tank bioreactor (STB). However, production in larger volumes is limited by the stability of the BEV s and amount of BEV s needed to achieve the target MOI of 3 per BEV. Here, the production parameters were optimized and the baculovirus stability was determined. Methods: The stability of the three types of baculovirus used to produce rAAV was determined for six expansion passages by protein expression analysis. To economize baculovirus, MOI and cell density at time of infection (TOI) were evaluated initially at small scale and then applied to the 10 L scale. Results: An MOI = 0.03 and TOI cell density of 1 × 10 6 cells/mL produced high titer rAAV without comprising yield. To confirm the scalability of the process, rAAV was produced in a 10 L STB using the optimized parameters obtaining a 10× increase in yield (∼1 × 10 14 rAAV DNAse‐resistant particles per liter). Conclusion: These findings contribute to the process development for large‐scale production of rAAV for gene therapy applications and its commercialization. Copyright © 2007 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jgm.1092

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 54

Metadata

Authors
Negrete, A., Yang, L. C., Mendez, A. F., Levy, J. R., & Kotin, R. M.
Venue
The Journal of Gene Medicine
Publisher
Wiley
Published
2007-09-03
Volume
9
Issue
11
Pages
938-948
ISSN
  • 1099-498X (ISSN-L)
  • 1521-2254
OpenAlex
W1993891172
Cited by
54
References
2
FWCI
1.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.