Prevention of inpatient hypoglycemia with a real‐time informatics alert
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Severe hypoglycemia (SH), defined as a blood glucose (BG) <40 mg/dL, is associated with an increased risk of adverse clinical outcomes in inpatients. OBJECTIVE: To determine whether a predictive informatics hypoglycemia risk‐alert supported by trained nurse responders would reduce the incidence of SH in our hospital. DESIGN: A 5‐month prospective cohort intervention study. SETTING: Acute care medical floors in a tertiary care academic hospital in St. Louis, Missouri. PATIENTS: From 655 inpatients on designated medical floors with a BG of <90 mg/dL, 390 were identified as high risk for hypoglycemia by the alert system. MEASUREMENTS: The primary outcome was the incidence of SH occurring in high‐risk intervention versus high‐risk control patients. Secondary outcomes included: number of episodes of SH in all study patients, incidence of BG < 60 mg/dL and severe hyperglycemia with a BG >299 mg/dL, length of stay, transfer to a higher level of care, the frequency that high‐risk patient's orders were changed in response to the alert‐intervention process, and mortality. RESULTS: The alert process, when augmented by nurse‐physician collaboration, resulted in a significant decrease by 68% in the rate of SH in alerted high‐risk patients versus nonalerted high‐risk patients (3.1% vs 9.7%, P = 0.012). Rates of hyperglycemia were similar on intervention and control floors at 28% each. There was no difference in mortality, length of stay, or patients requiring transfer to a higher level of care. CONCLUSION: A real‐time predictive informatics‐generated alert, when supported by trained nurse responders, significantly reduced inpatient SH. Journal of Hospital Medicine 2014;9:621–626. © 2014 Society of Hospital Medicine
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cryer, P. E., Davis, S. N., & Shamoon, H. (2003) · Diabetes Care · doi:10.2337/diacare.26.6.1902 · Cited by 1,160
Hypoglycemia and risk of death in critically ill patients
The NICE-SUGAR Study Investigators (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1204942 · Cited by 1,009
Epidemiology of severe hypoglycemia in the diabetes control and complications trial
(1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)80085-z · Cited by 807
Epidemiology of severe hypoglycemia in the Diabetes Control and Complications Trial
(1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90605-w · Cited by 807
Increased mortality of patients with diabetes reporting severe hypoglycemia
McCoy, R. G., Van Houten, H. K., Ziegenfuss, J. Y., Shah, N. D., Wermers, R. A., & Smith, S. A. (2012) · Diabetes Care · doi:10.2337/dc11-2054 · Cited by 539
Hypoglycemia and clinical outcomes in patients with diabetes hospitalized in the general ward
Turchin, A., Matheny, M. E., Shubina, M., Scanlon, J. V., Greenwood, B., & Pendergrass, M. L. (2009) · Diabetes Care · doi:10.2337/dc08-2127 · Cited by 453
Miller, M. E., Bonds, D. E., Gerstein, H. C., Seaquist, E. R., Bergenstal, R. M., Calles-Escandon, J., Childress, R. D., Craven, T. E., Cuddihy, R. M., Dailey, G., et al. (2010) · BMJ · doi:10.1136/bmj.b5444 · Cited by 429
Association of Hypoglycemia and Cardiac Ischemia
Desouza, C., Salazar, H., Cheong, B., Murgo, J., & Fonseca, V. (2003) · Diabetes Care · doi:10.2337/diacare.26.5.1485 · Cited by 406
Implementation of a real-time computerized sepsis alert in nonintensive care unit patients*
Sawyer, A. M., Deal, E. N., Labelle, A. J., Witt, C., Thiel, S. W., Heard, K., Reichley, R. M., Micek, S. T., & Kollef, M. H. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e318205df85 · Cited by 169
Self-citation
Cited by
Sly, B., Russell, A. W., & Sullivan, C. (2022) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2021.104596 · Cited by 36
Multifaceted approach to reducing occurrence of severe hypoglycemia in a large healthcare system
Milligan, P. E., Bocox, M. C., Pratt, E., Hoehner, C. M., Krettek, J. E., & Dunagan, W. C. (2015) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp150077 · Cited by 24
Self-citationWan, Y.-K. J., Wright, M. C., McFarland, M. M., Dishman, D., Nies, M. A., Rush, A., Madaras-Kelly, K., Jeppesen, A., & Del Fiol, G. (2023) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocad203 · Cited by 11
Metadata
- Authors
- Kilpatrick, C. R., Elliott, M. B., Pratt, E., Schafers, S. J., Blackburn, M. C., Heard, K., McGill, J. B., Thoelke, M., & Tobin, G. S.
- Venue
- Journal of Hospital Medicine
- Publisher
- Wiley
- Published
- 2014-06-05
- Volume
- 9
- Issue
- 10
- Pages
- 621-626
- ISSN
- 1553-5592 (ISSN-L)
- 1553-5606
- OpenAlex
- W2111791285
- Cited by
- 41
- References
- 9
- FWCI
- 1.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.