The DOI matches its Crossref record.
Intracellular hydrogen peroxide and superoxide anion detection in endothelial cells
Abstract
One of the objectives of studying endothelial cells in vitro is to evaluate neutrophil-endothelial cell interactions including potential consequences of oxidant-mediated damage to the endothelial cell. Current under-standing of endothelial cell oxidative function is derived primarily from the measurement of extracellular products. We utilized 2 dyes, 2′,7′-dichlorofluorescin diacetate (DGFH-DA) and hydroethidine (HE), which measure hydrogen peroxide (H2O2) and superoxide anion (O2-) respectively, for their suitability to monitor oxidative mechanisms in endothelial cells and to provide a reliable measure of intracellular oxidants. Endothelial cells stained with DCFH-DA and stimulated with H2O2 exhibited an increase in the fluorescent product 2′,7′-dichlorofluorescein (DCF) (measure of intracellular H2O2) which peaked at 10 min. Endothelial cells stained with HE and stimulated with H2O2 exhibited an increase in the fluorescent product ethidium bromide (EB) (measure of intracellular O2-) which lasted for approximately 60 min. Superoxide dismutase increased DCF fluorescence in endothelial cells stimulated with H2O2 by 158%. Allopurinol (xanthine oxidase inhibitor) reduced DCF and EB fluorescence by 48% and 37% respectively in endothelial cells stimulated with H2O2. Catalase completely inhibited an increase in DCF or EB fluorescence in endothelial cells stimulated with H2O2. There was a direct correlation between mean DCF and EB fluorescence intensity and the concentration of H2O2 or the number of phorbol 12-myristate 13-acetate-activated neutrophils added to endothelial cells. We conclude from these studies that DCFH-DA and HE can be used to measure intracellular H2O2 and O2- in endothelial cells and that the xanthine oxidase pathway for intracellular O2- production accounts for approximately 40% of the total intracellular O2- generated in endothelial cells after stimulation with H2O2. The combination of image cytometry and flow cytometry will be important for future evaluations of endothelial cell function. J. Leukoc. Biol. 55: 253–258; 1994.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chandel, N. S., McClintock, D. S., Feliciano, C. E., Wood, T. M., Melendez, J. A., Rodriguez, A. M., & Schumacker, P. T. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.m001914200 · Cited by 2,000
Fluorescence probes used for detection of reactive oxygen species
Gomes, A., Fernandes, E., & Lima, J. L. F. C. (2005) · Journal of Biochemical and Biophysical Methods · doi:10.1016/j.jbbm.2005.10.003 · Cited by 1,844
Zamzami, N., Marchetti, P., Castedo, M., Decaudin, D., Macho, A., Hirsch, T., Susin, S. A., Petit, P. X., Mignotte, B., & Kroemer, G. (1995) · The Journal of experimental medicine · doi:10.1084/jem.182.2.367 · Cited by 1,567
The biochemistry of programmed cell death
Kroemer, G., Petit, P., Zamzami, N., Vayssière, J., & Mignotte, B. (1995) · The FASEB Journal · doi:10.1096/fasebj.9.13.7557017 · Cited by 990
Zhao, H., Kalivendi, S., Zhang, H., Joseph, J., Nithipatikom, K., Vásquez-Vivar, J., & Kalyanaraman, B. (2003) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(03)00142-4 · Cited by 803
Metadata
- Authors
- Carter, W. O., Naryanan, P. K., & Robinson, J. P.
- Venue
- Journal of Leukocyte Biology
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-02-01
- Volume
- 55
- Issue
- 2
- Pages
- 253-258
- ISSN
- 0741-5400 (ISSN-L)
- 1938-3673
- OpenAlex
- W2188751783
- Cited by
- 635
- References
- 0
- FWCI
- 4.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intracellular hydrogen peroxide and superoxide anion detection in endothelial cells. https://app.cochat.ai/papers/10.1002/jlb.55.2.253
- The paper
- Carter, W. O., Naryanan, P. K., & Robinson, J. P. (1994). Intracellular hydrogen peroxide and superoxide anion detection in endothelial cells. Journal of Leukocyte Biology. https://doi.org/10.1002/jlb.55.2.253
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.