Quantitation of surface CD14 on human monocytes and neutrophils
The DOI matches its Crossref record.
Abstract
The absolute number of membrane-expressed CD14, the most important endotoxin receptor, on human monocytes and neutrophils shows remarkable variation in the literature. To quantify these numbers two fluorescence methods using fluorescein isothiocyanate (FITC)-labeled monoclonal antibodies (mAb) were applied. A commercially available set of standard beads was used in flow cytometry to quantitate CD14 with eight different mAbs. Independent from their isotype the various mAbs showed minor differences and indicated that peripheral blood monocytes expressed 99,500–134,600 (115,400 ± 10,600) and neutrophils 1,900–4,400 (3,300 ± 800) CD14 receptors. There was no significant difference in CD14 expression on leukocytes in unprocessed freshly obtained whole blood and after a Ficoll isolation procedure. However, a short temperature shift resulted in a 1.3- to 1.6-fold upregulation of CD14. The results obtained with the reference beads were verified with fluorescence Scatchard analysis and spectrofluorometry using mAb 26ic-FITC and showed 109,500 CD14 per monocyte and 6,700 CD14 per neutrophil. For comparison the number of CD14 on the monocytic THP-1 cells and Fcγ-receptors on human leukocytes were determined using the reference beads and flow cytometry and gave results comparable to published data. Our data indicate that resting human monocytes express roughly 110,000 CD14 molecules on their surface using a simple fluorometric assay. Correct determination of the number of CD14 and other cell surface receptors is of importance in the monitoring of septic patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Receptors, Mediators, and Mechanisms Involved in Bacterial Sepsis and Septic Shock
Van Amersfoort, E. S., Van Berkel, T. J. C., & Kuiper, J. (2003) · Clinical Microbiology Reviews · doi:10.1128/cmr.16.3.379-414.2003 · Cited by 750
Alcoholic liver disease and the gut-liver axis
Szabo, G. (2010) · World Journal of Gastroenterology · doi:10.3748/wjg.v16.i11.1321 · Cited by 378
Hron, G., Kollars, M., Weber, H., Sagaster, V., Quehenberger, P., Eichinger, S., Kyrle, P. A., & Weltermann, A. (2007) · Thrombosis and Haemostasis · doi:10.1160/th06-03-0141 · Cited by 296
Schutte, R. J., Parisi‐Amon, A., & Reichert, W. M. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31863 · Cited by 161
Metadata
- Authors
- Antal-Szalmas, P., van Strijp, J. A. G., Weersink, A. J. L., Verhoef, J., & van Kessel, K. P. M.
- Venue
- Journal of Leukocyte Biology
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-06-01
- Volume
- 61
- Issue
- 6
- Pages
- 721-728
- ISSN
- 0741-5400 (ISSN-L)
- 1938-3673
- OpenAlex
- W1860481694
- Cited by
- 170
- References
- 0
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitation of surface CD14 on human monocytes and neutrophils. https://app.cochat.ai/papers/10.1002/jlb.61.6.721
- The paper
- Antal-Szalmas, P., van Strijp, J. A. G., Weersink, A. J. L., Verhoef, J., & van Kessel, K. P. M. (1997). Quantitation of surface CD14 on human monocytes and neutrophils. Journal of Leukocyte Biology. https://doi.org/10.1002/jlb.61.6.721
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.