CoChat

In vivo strain in the humerus of pigeons (Columba livia) during flight

Biewener, A. A., Dial, K. P. · 1995 · Journal of Morphology
Cited by 132

The DOI matches its Crossref record.

Abstract

Longitudinal and principal strain recordings were made in vivo at three sites (dorsal, anterior, and ventral) on the humeral midshaft of pigeons executing five modes of free flight: Take‐off, level flight, landing, vertical ascent, and near‐vertical descent. Strains were also recorded while the birds flew carrying weights that were 33%, 50%, or 100% of their body weight. The relative distribution of strain measured at the three surface midshaft sites and across the bone's cortex was found to be similar for all flight modes. Principal strains recorded in the dorsal and ventral humerus indicated considerable torsion produced by aerodynamic loading of the wing surface posterior to the bone. Measured torsional shear strains (maximum: 2,700–4,150 μ ε during level flight) were 1.5 times greater than longitudinal strains. In addition to torsion, the humerus is also subjected to significant dorsoventral bending owing to lift forces acting on the wing during the downstroke. Analysis of the cross‐sectional distribution of longitudinal strains at the humeral midshaft cortex shows that the orientation of bending shifts in a regular manner during the downstroke, indicating that the wing generates progressively more thurst (vs. lift) later in the downstroke. This shift is less during take‐off and vertical ascent when greater lift is required. Peak principal and longitudinal strains increased by an average of only 50% from landing to vertical ascending flight and take‐off (e.g., dorsal humerus: −1,503 to −2,329 μ ε) and did not exceed −2,600 μ epsiv; at any site, even when the birds flew carrying twice their body weight. Strains recorded when birds flew at two times their body weight (100% BW load) were similar in magnitude to those recorded during vertical ascent and take‐off and likely represent those developed during maximal performance. Strains developed within the midshaft were maximal in the anterodorsal and posteroventral cortices, not at the dorsal, ventral, and anterior sites at which strain was recorded. Consequently, maximum strains experienced by the bone are probably 20–25% greater than those recorded (ca. 3,200 μ ε), indicating a safety factor of about 3.5 for compressive strain failure. The much higher shear strains, however, indicate a lower safety factor (1.9), in which the bone's torsional strength is its most critical design feature. Finally, the magnitude and distribution of strains developed in the humerus of pigeons are generally similar to those recorded in the humerus of large fruit‐eating bats during flight. © 1995 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmor.1052250106

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 132

Metadata

Authors
Biewener, A. A., & Dial, K. P.
Venue
Journal of Morphology
Publisher
Wiley
Published
1995-07
Volume
225
Issue
1
Pages
61-75
ISSN
  • 0362-2525 (ISSN-L)
  • 1097-4687
OpenAlex
W2028268473
Cited by
132
References
0
FWCI
9.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vivo strain in the humerus of pigeons (Columba livia) during flight. https://app.cochat.ai/papers/10.1002/jmor.1052250106
The paper
Biewener, A. A., & Dial, K. P. (1995). In vivo strain in the humerus of pigeons (Columba livia) during flight. Journal of Morphology. https://doi.org/10.1002/jmor.1052250106

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.