The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Renal diffusion and BOLD MRI in experimental diabetic nephropathy
Abstract
Purpose: To investigate the possibility of using combined blood oxygen level‐dependent (BOLD) imaging and diffusion‐weighted imaging (DWI) to detect pathological and physiological changes in renal tissue damage of the kidney induced by chronic renal hyperfiltration. Materials and Methods: The apparent diffusion coefficient (ADC) and the T 2* value within the inner compartments of the kidneys of 17 rats with diabetes mellitus were compared with the results obtained from a control group (N = 16). The influence of dynamic changes of the renal function on the blood‐oxygen saturation was evaluated by comparing the T 2* values before and after the active reduction of tubular transport by furosemide injection. Results: All compartments of the diabetic kidney showed significantly (P < 0.05) lower T 2*‐values compared to the control group. In particular, the very low values in the outer stripe (OS) of the outer medulla (OM) (T 2*‐normal: 69.4 ± 10.9 msec; T 2*‐diabetic: 51.4 ± 13.9 msec) indicated either hypoxia due to hyperfiltration, or renal blood volume changes. Diffusion imaging of the same area showed significantly lower ADC values (ADC‐normal: 1.45 ± 0.26; ADC‐edema: 1.19 ± 0.25 [10–9 m 2/s]) that correlated with pathological findings on histopathology. The injection of furosemide significantly (P < 0.05) increased T 2* in all compartments of both populations while the ADC remained unchanged. Conclusion: BOLD‐contrast imaging appears to be able to depict tissue at risk from ischemia by revealing information about the balance between tubular workload and delivery of oxygen, and thus may reflect a measure of the reserve capacity. The diffusion measurements apparently reveal J. Magn. Reson. Imaging 2003;17:104–113. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Invited. Ultrafast MR imaging of the abdomen: Echo planar imaging and diffusion‐weighted imaging
Yamashita, Y., Tang, Y., & Takahashi, M. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080216 · Cited by 92
Cited by
Role of hypoxia in the pathogenesis of renal disease
Eckardt, K.-U., Bernhardt, W. W., Weidemann, A., Warnecke, C., Rosenberger, C., Wiesener, M. M., & Willam, C. (2005) · Kidney International · doi:10.1111/j.1523-1755.2005.09909.x · Cited by 277
Hansell, P., Welch, W. J., Blantz, R. C., & Palm, F. (2013) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/1440-1681.12034 · Cited by 269
Pathophysiology of the Diabetic Kidney
Vallon, V., & Komers, R. (2011) · Comprehensive Physiology · doi:10.1002/cphy.c100049 · Cited by 259
Hesp, A. C., Schaub, J. A., Prasad, P. V., Vallon, V., Laverman, G. D., Bjornstad, P., & van Raalte, D. H. (2020) · Kidney International · doi:10.1016/j.kint.2020.02.041 · Cited by 202
Hypoxia-inducible factors and diabetes
Gunton, J. E. (2020) · Journal of Clinical Investigation · doi:10.1172/jci137556 · Cited by 159
Metadata
- Authors
- Ries, M., Basseau, F., Tyndal, B., Jones, R., Deminière, C., Catargi, B., Combe, C., Moonen, C. W. T., & Grenier, N.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2002-12-23
- Volume
- 17
- Issue
- 1
- Pages
- 104-113
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2072522516
- Cited by
- 228
- References
- 1
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Renal diffusion and BOLD MRI in experimental diabetic nephropathy. https://app.cochat.ai/papers/10.1002/jmri.10224
- The paper
- Ries, M., Basseau, F., Tyndal, B., Jones, R., Deminière, C., Catargi, B., Combe, C., Moonen, C. W. T., & Grenier, N. (2003). Renal diffusion and BOLD MRI in experimental diabetic nephropathy. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10224
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.