Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 379

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A single breath‐hold multiecho T2* cardiovascular magnetic resonance technique for diagnosis of myocardial iron overload

Open access
Westwood, Mark, Anderson, Lisa J., Firmin, David N., Gatehouse, Peter D., Charrier, Clare C., Wonke, Beatrix, Pennell, Dudley J.·2003·Journal of Magnetic Resonance Imaging

Abstract

Purpose: To assess tissue iron concentrations by the use of a gradient echo T2* multiecho technique. Materials and Methods: We compared the results of measurements of heart T2* from 32 patients using the established multiple breath‐hold variable TR technique with a new multiecho sequence that acquires all images within a single breath‐hold with constant TR. Results: There was good agreement of myocardial T2* values between both methods in the abnormal range of T2* < 20 msec (mean difference 0.2msec, 95% CI −1.3 to 0.9 msec, r = 0.97, P < 0.0001). The coefficient of variability between the methods was 3.5%. The interstudy reproducibility using the multiecho sequence had a variability coefficient of 2.3% in the abnormal T2* range and 5.8% over all T2* values. There was good agreement between the techniques for the liver T2* values. Conclusions: The use of the single breath‐hold, multiecho acquisition allowed reliable quantification of myocardial T2*. The good reproducibility, speed, and T1 independence of this technique allows greater accuracy, faster patient throughput, and, therefore, reduced costs (which is important in developing countries where thalassemia is most prevalent). J. Magn. Reson. Imaging 2003;18:33–39. © 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.10332

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 379

Metadata

Authors
Westwood, M., Anderson, L. J., Firmin, D. N., Gatehouse, P. D., Charrier, C. C., Wonke, B., & Pennell, D. J.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2003-06-13
Volume
18
Issue
1
Pages
33-39
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2098484245
Cited by
379
References
1
FWCI
10.35
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A single breath‐hold multiecho T2* cardiovascular magnetic resonance technique for diagnosis of myocardial iron overload. https://app.cochat.ai/papers/10.1002/jmri.10332
The paper
Westwood, M., Anderson, L. J., Firmin, D. N., Gatehouse, P. D., Charrier, C. C., Wonke, B., & Pennell, D. J. (2003). A single breath‐hold multiecho T2* cardiovascular magnetic resonance technique for diagnosis of myocardial iron overload. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10332

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.