Single‐shot spiral image acquisition with embedded z‐shimming for susceptibility signal recovery
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose: To efficiently and effectively recover the susceptibility‐induced signal losses for functional MRI (fMRI) experiments. Materials and Methods: The signal losses near air/tissue interfaces at the ventral brain regions introduce difficulties in the neuroimaging studies concerned with brain functions such as memory, emotion, and olfaction processes. The z‐shimming technique has been introduced in fMRI image acquisition to recover such losses. One significant drawback of such an approach is its time consuming nature. In this report, a single‐shot spiral imaging method, which combines spiral‐in and spiral‐out acquisitions along with embedded z‐shimming gradient, was proposed and implemented to achieve signal recovery without sacrificing temporal resolution. Results: Using the proposed method, final images were shown in the ventral brain regions. The images were acquired with a throughput of 16 slices/second and demonstrated effectiveness and efficiency in signal recovery near air/tissue interfaces. Conclusion: Uniform recovery can be achieved efficiently near air/tissue interfaces where susceptibility‐induced spatial gradients are pronounced. We anticipate that our method would be well suited for fMRI studies involving the ventral brain areas. J. Magn. Reson. Imaging 2003;18:389–395. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Cited by
Functional Imaging of Numerical Processing in Adults and 4-y-Old Children
Cantlon, J. F., Brannon, E. M., Carter, E. J., & Pelphrey, K. A. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040125 · Cited by 611
Pelphrey, K. A., Morris, J. P., & McCarthy, G. (2004) · Journal of Cognitive Neuroscience · doi:10.1162/0898929042947900 · Cited by 454
Huettel, S. A., Song, A. W., & McCarthy, G. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.5070-04.2005 · Cited by 454
Self-citationNeural basis of eye gaze processing deficits in autism
Pelphrey, K. A., Morris, J. P., & McCarthy, G. (2005) · Brain · doi:10.1093/brain/awh404 · Cited by 446
Pelphrey, K. A., Morris, J. P., Michelich, C. R., Allison, T., & McCarthy, G. (2005) · Cerebral Cortex · doi:10.1093/cercor/bhi064 · Cited by 369
Metadata
- Authors
- Guo, H., & Song, A. W.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2003-08-18
- Volume
- 18
- Issue
- 3
- Pages
- 389-395
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2029097094
- Cited by
- 41
- References
- 1
- FWCI
- 4.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single‐shot spiral image acquisition with embedded z‐shimming for susceptibility signal recovery. https://app.cochat.ai/papers/10.1002/jmri.10355
- The paper
- Guo, H., & Song, A. W. (2003). Single‐shot spiral image acquisition with embedded z‐shimming for susceptibility signal recovery. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10355
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.