Enhanced gray and white matter contrast of phase susceptibility‐weighted images in ultra‐high‐field magnetic resonance imaging
Open accessThe DOI matches its Crossref record.
Abstract
Purpose: To evaluate if magnetic susceptibility sensitive phase postprocessed images can be used to enhance the inherent brain/gray white matter contrast in gradient echo (GE) images at 8‐Tesla (T) magnetic resonance (MR). Materials and Methods: Phase and magnitude images of high‐resolution GE MR 8‐T images were created. Comparisons were made between the magnitude, the product of the magnitude and phase, and pure phase images. Results: The pure phase images significantly improved the contrast between the gray and white matter structures. In general, the higher the iron content or subvoxel field inhomogeneities, the higher was the contrast, and the greater were the resultant phase shifts. The phase images best demonstrated anatomy that was not apparent on the standard magnitude images. Conclusion: Phase imaging can significantly improve the demonstration of the internal anatomical brain structures over standard magnitude GE imaging techniques at high field. J. Magn. Reson. Imaging 2003;18:284–290. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113
Schweser, F., Deistung, A., Lehr, B. W., & Reichenbach, J. R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.070 · Cited by 710
High-field MRI of brain cortical substructure based on signal phase
Duyn, J. H., van Gelderen, P., Li, T.-Q., de Zwart, J. A., Koretsky, A. P., & Fukunaga, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610821104 · Cited by 641
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Metadata
- Authors
- Abduljalil, A. M., Schmalbrock, P., Novak, V., & Chakeres, D. W.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2003-08-18
- Volume
- 18
- Issue
- 3
- Pages
- 284-290
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2053623659
- Cited by
- 128
- References
- 0
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced gray and white matter contrast of phase susceptibility‐weighted images in ultra‐high‐field magnetic resonance imaging. https://app.cochat.ai/papers/10.1002/jmri.10362
- The paper
- Abduljalil, A. M., Schmalbrock, P., Novak, V., & Chakeres, D. W. (2003). Enhanced gray and white matter contrast of phase susceptibility‐weighted images in ultra‐high‐field magnetic resonance imaging. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10362
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.