The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Diffusion tensor MRI of the human kidney
Open accessAbstract
This study characterizes the diffusion anisotropy of the human kidney using a diffusion‐weighted, single‐shot echo planar imaging (EPI) sequence in order to access the full apparent diffusion tensor (ADT) within one breathhold. The fractional anisotropy (FA) of the cortex and the medulla were found to be 0.22 ± 0.12 and 0.39 ± 0.11, respectively (N = 10), which emphasizes the need for rotationally invariant diffusion measurements for clinical applications. Additional limitations for clinical diffusion imaging on the kidney are the strong susceptibility variations within the abdomen that restrict the use of imaging techniques employing long echo trains, and the severe motion sensitivity that limits the available imaging time to one breath‐hold. To overcome these problems an isotropic, diffusion‐weighted, segmented EPI protocol that facilitates the acquisition of high‐resolution diffusion‐weighted images within a single breath‐hold was implemented. Using this method, the apparent diffusion coefficient (ADC) of the cortex and medulla were found to be 2.89 ± 0.28 · 10−9 m 2/s and 2.18 ± 0.36 · 10−9 m 2/s (N = 10). J. Magn. Reson. Imaging 2001;14:42–49. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Cited by
Ultrasound Elastography: Review of Techniques and Clinical Applications
Sigrist, R. M. S., Liau, J., Kaffas, A. E., Chammas, M. C., & Willmann, J. K. (2017) · Theranostics · doi:10.7150/thno.18650 · Cited by 1,877
Taouli, B., Vilgrain, V., Dumont, E., Daire, J.-L., Fan, B., & Menu, Y. (2003) · Radiology · doi:10.1148/radiol.2261011904 · Cited by 577
Intravoxel Incoherent Motion in Body Diffusion-Weighted MRI: Reality and Challenges
Koh, D.-M., Collins, D. J., & Orton, M. R. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5515 · Cited by 527
Extracranial applications of diffusion-weighted magnetic resonance imaging
Thoeny, H. C., & De Keyzer, F. (2007) · European Radiology · doi:10.1007/s00330-006-0547-0 · Cited by 269
Gennisson, J.-L., Grenier, N., Combe, C., & Tanter, M. (2012) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.04.013 · Cited by 260
Self-citation
Metadata
- Authors
- Ries, M., Jones, R. A., Basseau, F., Moonen, C. T. W., & Grenier, N.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2001-06-26
- Volume
- 14
- Issue
- 1
- Pages
- 42-49
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1969520658
- Cited by
- 236
- References
- 1
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion tensor MRI of the human kidney. https://app.cochat.ai/papers/10.1002/jmri.1149
- The paper
- Ries, M., Jones, R. A., Basseau, F., Moonen, C. T. W., & Grenier, N. (2001). Diffusion tensor MRI of the human kidney. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1149
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.