The DOI matches its Crossref record.
Magnetic resonance imaging of atherosclerotic plaques using superparamagnetic iron oxide particles
Abstract
Experimental data show accumulation of superparamagnetic iron oxide (SPIO) particles in atherosclerotic plaques. SPIO uptake occurred in plaques, suggesting an increased endothelial permeability and macrophage infiltrates as signs of inflammatory plaque activity. We incidentally observed SPIO uptake in aortic and arterial wall segments in patients who had originally received the magnetic resonance (MR) contrast agent for staging lymph node metastases. Twenty patients (19 male, 1 female; mean age, 64; range, 41–78 years) with bladder or prostate cancer underwent MR imaging (MRI) using a T2*‐weighted high‐resolution gradient‐echo sequence prior to and 24–36 hours after intravenous injection of 2.6 mg of Fe/kg of SPIO (Sinerem®). The aorta, both common external and internal iliac, as well as both superficial femoral arteries, were retrospectively analyzed for atherosclerotic wall changes. One patient was excluded. A positive finding was defined as an area of pronounced signal loss on postcontrast images clearly confined to the arterial wall, which was absent in the precontrast examination or increased in size. Such a finding was observed in one to three arteries in 7 of the 19 patients. The pronounced signal loss in the wall of the aorta and pelvic arteries seen in part of an elderly patient population after intravenous SPIO administration strongly suggests that this contrast agent accumulates in human atherosclerotic plaques. J. Magn. Reson. Imaging 2001;14:355–361. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Kooi, M. E., Cappendijk, V. C., Cleutjens, K. B. J. M., Kessels, A. G. H., Kitslaar, P. J. E. H. M., Borgers, M., Frederik, P. M., Daemen, M. J. A. P., & van Engelshoven, J. M. A. (2003) · Circulation · doi:10.1161/01.cir.0000068315.98705.cc · Cited by 798
Superparamagnetic Iron Oxide Nanoparticle Probes for Molecular Imaging
Thorek, D. L. J., Chen, A. K., Czupryna, J., & Tsourkas, A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9002-7 · Cited by 772
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
Villaraza, A. J. L., Bumb, A., & Brechbiel, M. W. (2010) · Chemical Reviews · doi:10.1021/cr900232t · Cited by 632
Metadata
- Authors
- Schmitz, S. A., Taupitz, M., Wagner, S., Wolf, K., Beyersdorff, D., & Hamm, B.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2001-09-28
- Volume
- 14
- Issue
- 4
- Pages
- 355-361
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2107147441
- Cited by
- 208
- References
- 0
- FWCI
- 10.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic resonance imaging of atherosclerotic plaques using superparamagnetic iron oxide particles. https://app.cochat.ai/papers/10.1002/jmri.1194
- The paper
- Schmitz, S. A., Taupitz, M., Wagner, S., Wolf, K., Beyersdorff, D., & Hamm, B. (2001). Magnetic resonance imaging of atherosclerotic plaques using superparamagnetic iron oxide particles. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1194
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.