The DOI matches its Crossref record.
Magnetic resonance imaging of atherosclerotic plaques using superparamagnetic iron oxide particles
Abstract
Experimental data show accumulation of superparamagnetic iron oxide (SPIO) particles in atherosclerotic plaques. SPIO uptake occurred in plaques, suggesting an increased endothelial permeability and macrophage infiltrates as signs of inflammatory plaque activity. We incidentally observed SPIO uptake in aortic and arterial wall segments in patients who had originally received the magnetic resonance (MR) contrast agent for staging lymph node metastases. Twenty patients (19 male, 1 female; mean age, 64; range, 41–78 years) with bladder or prostate cancer underwent MR imaging (MRI) using a T2*‐weighted high‐resolution gradient‐echo sequence prior to and 24–36 hours after intravenous injection of 2.6 mg of Fe/kg of SPIO (Sinerem®). The aorta, both common external and internal iliac, as well as both superficial femoral arteries, were retrospectively analyzed for atherosclerotic wall changes. One patient was excluded. A positive finding was defined as an area of pronounced signal loss on postcontrast images clearly confined to the arterial wall, which was absent in the precontrast examination or increased in size. Such a finding was observed in one to three arteries in 7 of the 19 patients. The pronounced signal loss in the wall of the aorta and pelvic arteries seen in part of an elderly patient population after intravenous SPIO administration strongly suggests that this contrast agent accumulates in human atherosclerotic plaques. J. Magn. Reson. Imaging 2001;14:355–361. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanoparticle PEGylation for Imaging and Therapy
Jokerst, J. V., Lobovkina, T., Zare, R. N., & Gambhir, S. S. (2011) · Nanomedicine · doi:10.2217/nnm.11.19 · Cited by 2,046
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Kooi, M. E., Cappendijk, V. C., Cleutjens, K. B. J. M., Kessels, A. G. H., Kitslaar, P. J. E. H. M., Borgers, M., Frederik, P. M., Daemen, M. J. A. P., & van Engelshoven, J. M. A. (2003) · Circulation · doi:10.1161/01.cir.0000068315.98705.cc · Cited by 798
Superparamagnetic Iron Oxide Nanoparticle Probes for Molecular Imaging
Thorek, D. L. J., Chen, A. K., Czupryna, J., & Tsourkas, A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9002-7 · Cited by 772
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
Villaraza, A. J. L., Bumb, A., & Brechbiel, M. W. (2010) · Chemical Reviews · doi:10.1021/cr900232t · Cited by 632
Macrophage-targeted nanomedicine for the diagnosis and treatment of atherosclerosis
Chen, W., Schilperoort, M., Cao, Y., Shi, J., Tabas, I., & Tao, W. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00629-x · Cited by 518
Applications of nanoparticles for diagnosis and therapy of cancer
Baetke, S. C., Lammers, T., & Kiessling, F. (2015) · The British Journal of Radiology · doi:10.1259/bjr.20150207 · Cited by 494
Raynal, I., Prigent, P., Peyramaure, S., Najid, A., Rebuzzi, C., & Corot, C. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000101027.57021.28 · Cited by 403
Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles
Cunningham, C. H., Arai, T., Yang, P. C., McConnell, M. V., Pauly, J. M., & Conolly, S. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20477 · Cited by 403
Application of Light Scattering Techniques to Nanoparticle Characterization and Development
Carvalho, P. M., Felício, M. R., Santos, N. C., Gonçalves, S., & Domingues, M. M. (2018) · Frontiers in Chemistry · doi:10.3389/fchem.2018.00237 · Cited by 402
Emerging applications for ferumoxytol as a contrast agent in MRI
Bashir, M. R., Bhatti, L., Marin, D., & Nelson, R. C. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24691 · Cited by 371
Saam, T., Hatsukami, T. S., Takaya, N., Chu, B., Underhill, H., Kerwin, W. S., Cai, J., Ferguson, M. S., & Yuan, C. (2007) · Radiology · doi:10.1148/radiol.2441051769 · Cited by 331
Ji, X., Shao, R., Elliott, A. M., Stafford, R. J., Esparza-Coss, E., Bankson, J. A., Liang, G., Luo, Z.-P., Park, K., Markert, J. T., et al. (2007) · The Journal of Physical Chemistry C · doi:10.1021/jp0702245 · Cited by 326
Magnetic Particle Imaging (MPI) for NMR and MRI researchers
Saritas, E. U., Goodwill, P. W., Croft, L. R., Konkle, J. J., Lu, K., Zheng, B., & Conolly, S. M. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.029 · Cited by 307
Trivedi, R. A., U-King-Im, J.-M., Graves, M. J., Cross, J. J., Horsley, J., Goddard, M. J., Skepper, J. N., Quartey, G., Warburton, E., Joubert, I., et al. (2004) · Stroke · doi:10.1161/01.str.0000131268.50418.b7 · Cited by 301
Modo, M., Hoehn, M., & Bulte, J. W. M. (2005) · Molecular Imaging · doi:10.1162/15353500200505145 · Cited by 294
Clinical Indications for Cardiovascular Magnetic Resonance (CMR): Consensus Panel Report #
Pennell, D., Sechtem, U., Higgins, C., Manning, W., Pohost, G., Rademakers, F., van Rossum, A., Shaw, L., & Kent Yucel, E. (2004) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-200038581 · Cited by 274
Nanoparticles for Imaging: top or Flop?
Kiessling, F., Mertens, M. E., Grimm, J., & Lammers, T. (2014) · Radiology · doi:10.1148/radiol.14131520 · Cited by 228
SPION primes THP1 derived M2 macrophages towards M1-like macrophages
Laskar, A., Eilertsen, J., Li, W., & Yuan, X.-M. (2013) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2013.10.115 · Cited by 138
Briley-Saebo, K. C., Cho, Y. S., Shaw, P. X., Ryu, S. K., Mani, V., Dickson, S., Izadmehr, E., Green, S., Fayad, Z. A., & Tsimikas, S. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.023 · Cited by 128
The iron hypothesis of atherosclerosis and its clinical impact
Yuan, X., & Li, W. (2003) · Annals of Medicine · doi:10.1080/07853890310016342 · Cited by 93
Metadata
- Authors
- Schmitz, S. A., Taupitz, M., Wagner, S., Wolf, K., Beyersdorff, D., & Hamm, B.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2001-09-28
- Volume
- 14
- Issue
- 4
- Pages
- 355-361
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2107147441
- Cited by
- 208
- References
- 0
- FWCI
- 10.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.