The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Functional cardiac MR imaging with steady‐state free precession (SSFP) significantly improves endocardial border delineation without contrast agents
Open accessAbstract
Contrast between blood and myocardium in standard turbo gradient echo MR techniques (TFE) used routinely in clinical practice is mainly caused by unsaturated inflowing blood. Steady‐state free precession (SSFP) has excellent contrast even in the absence of inflow effects. In 45 subjects cardiac cine loops in two long axis projections were acquired using TFE and compared with SSFP. A visual score (range 0 worst – 3 best) was assigned for endocardial border delineation for six myocardial segments in two long axis views. Endocardial border delineation score for TFE was 1.3 ± 0.3 per segment and 2.4 ± 0.3 for SSFP (P < 0.0001). Signal intensity blood/signal intensity myocardium was 1.5 ± 0.4 at enddiastole and 1.4 ± 0.3 at systole for TFE and 3.5 ± 1.1 and 3.2 ± 1.3 for SSFP, respectively (P < 0.0001). SSFP increases contrast between blood and myocardium more than twofold, resulting in an improved endocardial border definition. This may reduce variability for the determination of cardiac volumes and ejection fraction. J. Magn. Reson. Imaging 2001;14:362–367. ©2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
In Vivo mouse imaging and spectroscopy in drug discovery
Beckmann, N., Kneuer, R., Gremlich, H., Karmouty‐Quintana, H., Blé, F., & Müller, M. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1153 · Cited by 118
Metadata
- Authors
- Thiele, H., Nagel, E., Paetsch, I., Schnackenburg, B., Bornstedt, A., Kouwenhoven, M., Wahl, A., Schuler, G., & Fleck, E.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2001-09-28
- Volume
- 14
- Issue
- 4
- Pages
- 362-367
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2086679255
- Cited by
- 218
- References
- 1
- FWCI
- 9.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Functional cardiac MR imaging with steady‐state free precession (SSFP) significantly improves endocardial border delineation without contrast agents. https://app.cochat.ai/papers/10.1002/jmri.1195
- The paper
- Thiele, H., Nagel, E., Paetsch, I., Schnackenburg, B., Bornstedt, A., Kouwenhoven, M., Wahl, A., Schuler, G., & Fleck, E. (2001). Functional cardiac MR imaging with steady‐state free precession (SSFP) significantly improves endocardial border delineation without contrast agents. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1195
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.