CoChat

Rapid three‐dimensional T1‐weighted MR imaging with the MP‐RAGE sequence

Mugler, John P., Brookeman, James R. · 1991 · Journal of Magnetic Resonance Imaging
Cited by 174

The DOI matches its Crossref record.

Abstract

The authors investigated the application of three‐dimensional (3D) magnetization‐prepared rapid gradient‐echo (MP‐RAGE) imaging to the acquisition of small (32 × 128 × 256) T1‐weighted 3D data sets with imaging times of approximately 1 minute. A theoretical model was used to study the contrast behavior of brain tissue. On the basis of these theoretical results, 3D MP‐RAGE sequences were implemented on a 1.5‐T whole‐body imager. Thirty‐two‐section 3D data sets demonstrating good signal‐to‐noise ratios and resolution and strong T1‐weighted contrast were obtained in 1 minute. Compared with standard short TR/TE spin‐echo sequences with the same imaging times and comparable sequence parameters, the 3D MP‐RAGE sequence delivered increases of more than 50% in the white matter/gray matter signal difference‐to‐noise and white matter signal‐to‐noise ratios, and provided almost twice as many sections. These sequences may find a clinical role in 3D scout imaging and screening and in patients with claustrophobia or trauma.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.1880010509

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Mugler, J. P., & Brookeman, J. R.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
1991-09
Volume
1
Issue
5
Pages
561-567
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2139209606
Cited by
174
References
0
FWCI
1.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.