The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Imaging artifacts at 3.0T
Abstract
Clinical MRI at a field strength of 3.0T is finding increasing use. However, along with the advantages of 3.0T, such as increased SNR, there can be drawbacks, including increased levels of imaging artifacts. Although every imaging artifact observed at 3.0T can also be present at 1.5T, the intensity level is often higher at 3.0T and thus the artifact is more objectionable. This review describes some of the imaging artifacts that are commonly observed with 3.0T imaging, and their root causes. When possible, countermeasures that reduce the artifact level are described. J. Magn. Reson. Imaging 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Discrete-time Signal Processing
Williamson, D. (1999) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0541-1 · Cited by 4,858
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Handbook of MRI Pulse Sequences
(2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,610
Schenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Automatic, localized in Vivo adjustment of all first‐and second‐order shim coils
Gruetter, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290613 · Cited by 870
de Bazelaire, C. M. J., Duhamel, G. D., Rofsky, N. M., & Alsop, D. C. (2004) · Radiology · doi:10.1148/radiol.2303021331 · Cited by 792
Cited by
Fratz, S., Chung, T., Greil, G. F., Samyn, M. M., Taylor, A. M., Valsangiacomo Buechel, E. R., Yoo, S.-J., & Powell, A. J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-51 · Cited by 507
A Hitchhiker's Guide to Functional Magnetic Resonance Imaging
Soares, J. M., Magalhães, R., Moreira, P. S., Sousa, A., Ganz, E., Sampaio, A., Alves, V., Marques, P., & Sousa, N. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00515 · Cited by 272
Van de Moortele, P.-F., Auerbach, E. J., Olman, C., Yacoub, E., Uğurbil, K., & Moeller, S. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.009 · Cited by 265
Structural brain development: A review of methodological approaches and best practices
(2017) · doi:10.1016/j.dcn.2017.11.008 · Cited by 124
Chung, A. W., Seunarine, K. K., & Clark, C. A. (2016) · Human Brain Mapping · doi:10.1002/hbm.23328 · Cited by 63
Metadata
- Authors
- Bernstein, M. A., Huston, J., & Ward, H. A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2006-09-06
- Volume
- 24
- Issue
- 4
- Pages
- 735-746
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1999960294
- Cited by
- 255
- References
- 62
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging artifacts at 3.0T. https://app.cochat.ai/papers/10.1002/jmri.20698
- The paper
- Bernstein, M. A., Huston, J., & Ward, H. A. (2006). Imaging artifacts at 3.0T. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.20698
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.