The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Contrast-enhanced MR imaging of liver and spleen: first experience in humans with a new superparamagnetic iron oxide
Abstract
The aim of this prospective study was to obtain the first human safety and magnetic resonance (MR) imaging results with a new formulation of superparamagnetic iron oxide (SPIO) (SHU 555 A). The SPIO was tested at four iron doses, from 5 to 40 mumol/kg. Laboratory tests and clinical measurements were done in 32 healthy volunteers for up to 3 weeks after administration. MR imaging at 1.5 T was performed before and 8 hours to 14 days after fast intravenous injection (500 mumol Fe/min) of the SPIO (six subjects per dose). Results of this phase I study demonstrate that SHU 555 A at a concentration of 0.5 mol Fe/L was well tolerated. A dose-dependent minor increase in activated partial thromboplastin time, which remained within the normal range, was seen. All doses of SPIO caused a signal loss in both liver and spleen (P < .05) with a spin-echo sequence (TR = 2,300 msec, TE = 45 msec). The signal losses in the liver 8 hours after contrast agent injection were 58%, 79%, 82%, and 87% for the 5, 10, 20, and 40 mumol Fe/kg doses, respectively. The corresponding signal losses in the spleen were 23%, 45%, 65%, and 78%, respectively. The doses that reduced signal intensity by half were 3.1 mumol Fe/kg for the liver and 12.8 mumol Fe/kg for the spleen. The results suggest that the new SPIO formulation is a safe and efficient MR contrast agent.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A clinical study assessing the toxicity of ferumcarbotran reported adverse effects such as irritation at the site of injection, pain and headache, which were all only observed in a small subset of individuals [134].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [134]
Citations
Cites
Superparamagnetic iron oxide: pharmacokinetics and toxicity
Weissleder, R., Stark, D., Engelstad, B. L., Bacon, B., Compton, C. C., White, D., Jacobs, P. M., & Lewis, J. M. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.1.167 · Cited by 1,045
Weissleder, R., Elizondo, G., WITTENBERG, J., Rabito, C. A., Bengele, H. H., & Josephson, L. (1990) · Radiology · doi:10.1148/radiology.175.2.2326474 · Cited by 1,027
Superparamagnetic iron oxide: clinical application as a contrast agent for MR imaging of the liver.
Stark, D. D., Weissleder, R., Elizondo, G., Hahn, P. F., Saini, S., Todd, L. E., WITTENBERG, J., & Ferrucci, J. T. (1988) · Radiology · doi:10.1148/radiology.168.2.3393649 · Cited by 512
Book of Abstracts, Society of Magnetic Resonance in Medicine
Tanttu, J. I., & SEPPONEN, R. E. (1993) · Cited by 394
Heiken, J. P., Weyman, P. J., Lee, J. K., Balfe, D. M., Picus, D. D., Brunt, E. M., & Flye, M. W. (1989) · Radiology · doi:10.1148/radiology.171.1.2538862 · Cited by 312
Iron oxide-enhanced MR imaging of the liver and spleen: review of the first 5 years
Ferrucci, J. T., & Stark, D. D. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.155.5.2120963 · Cited by 279
Nelson, R. C., CHEZMAR, J. L., Sugarbaker, P. H., & Bernardino, M. E. (1989) · Radiology · doi:10.1148/radiology.172.1.2662254 · Cited by 248
Focal liver lesions: MR imaging with Mn-DPDP--initial clinical results in 40 patients.
Hamm, B., Vogl, T. J., Branding, G., Schnell, B., Taupitz, M., Wolf, K. J., & Lissner, J. (1992) · Radiology · doi:10.1148/radiology.182.1.1309218 · Cited by 173
Semelka, R. C., Shoenut, J. P., Kroeker, M. A., Greenberg, H. M., Simm, F. C., Minuk, G. Y., Kroeker, R. M., & Micflikier, A. B. (1992) · Radiology · doi:10.1148/radiology.184.3.1324509 · Cited by 166
Hepatic metastases: randomized, controlled comparison of detection with MR imaging and CT.
Stark, D. D., WITTENBERG, J., Butch, R. J., & Ferrucci, J. T. (1987) · Radiology · doi:10.1148/radiology.165.2.3310094 · Cited by 150
Flagged first, then by citations
Research works printed but not linked: 2
- Harker LA, 1991, Future directions, Semin Hematol, 28, 73
- World Health Organization, 1989, Radiocontrast media: labelling changes, FDA Drug Bull, 19, 138
Cited by
Sorted by citations
Items 101–187 of 187
Araya, T., Kasahara, Nishikawa, Kimura, Sone, Nagae, Ikehata, Nagano, & Fujimura, F. (2013) · OncoTargets and Therapy · doi:10.2147/ott.s42815 · Cited by 23
Narkhede, A. A., Sherwood, J. A., Antone, A. J., Coogan, K. R., Bolding, M., Deb, S., Bao, Y., & Rao, S. S. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b00606 · Cited by 23
Time Course of Biodistribution and Heat Generation of Magnetite Cationic Liposomes in Mouse Model
Itô, A., Nakahara, Y., Tanaka, K., Kuga, Y., Honda, H., & Kobayashi, T. (2003) · Thermal Medicine(Japanese Journal of Hyperthermic Oncology) · doi:10.3191/thermalmedicine.19.151 · Cited by 23
Functionalised iron oxide nanoparticles for multimodal optoacoustic and magnetic resonance imaging
Bell, G., Balasundaram, G., Attia, A. B. E., Mandino, F., Olivo, M., & Parkin, I. P. (2019) · Journal of Materials Chemistry B · doi:10.1039/c8tb02299b · Cited by 22
Hundt, W., Petsch, R., Helmberger, T. K., & Reiser, M. F. (2000) · European Radiology · doi:10.1007/s003300050067 · Cited by 22
Wersebe, A., Wiskirchen, J., Decker, U., Schick, F., Dietz, K., ller-Schimpfle, M. M., Claussen, C. D., & Pereira, P. L. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000188359.72928.0f · Cited by 22
Arbab, A. S., Ichikawa, T., Araki, T., Toyama, K., Nambu, A., Ohsawa, S., Kumagai, H., & Aikawa, Y. (2000) · Abdominal Imaging · doi:10.1007/s002619910035 · Cited by 22
Tokunaga, S., Koda, M., Matono, T., Sugihara, T., Nagahara, T., Ueki, M., Murawaki, Y., Kakite, S., & Yamashita, E. (2012) · British Journal of Radiology · doi:10.1259/bjr/64518148 · Cited by 21
Iron oxide nanoparticles attenuate T helper 17 cell responses in vitro and in vivo
Hsiao, Y.-P., Shen, C., Huang, C., Lin, Y., & Jan, T. (2018) · International Immunopharmacology · doi:10.1016/j.intimp.2018.03.007 · Cited by 21
Onishi, H., Murakami, T., Kim, T., Hori, M., Hirohashi, S., Matsuki, M., Narumi, Y., Imai, Y., Sakurai, K., & Nakamura, H. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21608 · Cited by 21
Magnetic Nanoparticle Assisted Molecular MR Imaging
Jun, Y., Jang, J.-T., & Cheon, J. (2007) · Advances in experimental medicine and biology · doi:10.1007/978-0-387-76713-0_7 · Cited by 21
Filler, A. G., & Lever, A. M. L. (1997) · AIDS Research and Human Retroviruses · doi:10.1089/aid.1997.13.291 · Cited by 20
MRI in the Evaluation of Hepatocellular Nodules: Role of Pulse Sequences and Contrast Agents
Ichikawa, T. (2004) · Intervirology · doi:10.1159/000078477 · Cited by 20
Harisinghani, M. G., Saini, S., Weissleder, R., Rubin, D. L., DeLange, E. E., Harms, S. E., Weinreb, J. C., Small, W. C., Sukerkar, A. N., Brown, J. J., et al. (2001) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200109000-00017 · Cited by 20
Automatic vessel segmentation using active contours in cine phase contrast flow measurements
Kozerke, S., Botnar, R. M., Oyre, S., Scheidegger, M. B., Pedersen, E. M., & Boesiger, P. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199907)10:1 · Cited by 98
Fukuda, K., Mori, K., Hasegawa, N., Nasu, K., Ishige, K., Okamoto, Y., Shiigai, M., Abei, M., Minami, M., & Hyodo, I. (2019) · Japanese Journal of Radiology · doi:10.1007/s11604-019-00843-1 · Cited by 19
Bellenger, N. G., Gatehouse, P. D., Rajappan, K., Keegan, J., Firmin, D. N., & Pennell, D. J. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(200004)11:4 · Cited by 36
Lee, J., Kumari, N., Kim, S. M., Kim, S., Jeon, K., Im, G. H., Jang, M.-S., Lee, W. J., Lee, J. H., & Lee, I. S. (2018) · Chemistry of Materials · doi:10.1021/acs.chemmater.8b00854 · Cited by 18
Park, Y. J., Nah, S. H., Lee, J. Y., Jeong, J. M., Chung, J. K., Lee, M. C., Yang, V. C.-M., & Lee, S. J. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10167 · Cited by 18
Bell, G., Bogart, L. K., Southern, P., Olivo, M., Pankhurst, Q. A., & Parkin, I. P. (2017) · European Journal of Inorganic Chemistry · doi:10.1002/ejic.201601432 · Cited by 17
The characterization of liver tumours by MRI
Robinson, P. J. A. (1996) · Clinical Radiology · doi:10.1016/s0009-9260(96)80002-x · Cited by 17
Iron oxide nanoparticles trigger endoplasmic reticulum damage in steatotic hepatic cells
Uzhytchak, M., Lunová, M., Smolková, B., Jirsa, M., Dejneka, A., & Lunov, O. (2023) · Nanoscale Advances · doi:10.1039/d3na00071k · Cited by 16
Gao, S. W., George, S. J., & Zhou, Z. (2016) · Dalton Transactions · doi:10.1039/c5dt04172d · Cited by 15
NANOTECHNOLOGY IN CANCER THERAPY
Dhiman, V., Seth, N., & Kumar, S. L. H. (2013) · Journal of Drug Delivery and Therapeutics · doi:10.22270/jddt.v3i5.616 · Cited by 14
Alger, J. R., Harreld, J. H., Chen, S. C., Mintorovitch, J., & Lu, D. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1223 · Cited by 14
Remmele, S., Ring, J., Sénégas, J., Heindel, W. L., Mesters, R. M., Bremer, C., & ten Persigehl, T. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22810 · Cited by 13
Magnetic resonance imaging findings of atypical focal nodular hyperplasia of the liver
Asbach, P., Klessen, C., Koch, M., Hamm, B., & Taupitz, M. (2007) · Clinical Imaging · doi:10.1016/j.clinimag.2007.03.003 · Cited by 13
Salimi, M., Kuddannaya, S., & Bulte, J. W. M. (2024) · Nano Letters · doi:10.1021/acs.nanolett.4c03553 · Cited by 13
Ishida, T., Murakami, T., Kato, N., Takahashi, M., Miyazawa, T., Tsuda, K., Tomoda, K., Narumi, Y., & Nakamura, H. (1997) · Investigative Radiology · doi:10.1097/00004424-199705000-00005 · Cited by 12
Halig, L. V., Wang, D., Wang, A. Y., Chen, Z. G., & Fei, B. (2013) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2006492 · Cited by 11
Evaluation of the Time Window for Resovist-Enhanced T2-Weighted MRI of the Liver
Reimer, P., Müller, M., Marx, C., & Balzer, T. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80222-2 · Cited by 11
Hwang, S., Park, J. S., Cho, W., Park, H. J., Cha, K.-H., Ha, D.-C., Choi, Y.-W., Lee, H., & Cho, S. H. (2013) · International Journal of Nanomedicine · doi:10.2147/ijn.s51684 · Cited by 11
Chung, Y. E., Park, M., Kim, M. S., Kim, E., Park, J., Song, H., Choi, J., Kim, M., & Kim, K. W. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22184 · Cited by 10
Bildgebende Diagnostik bei Milzerkrankungen
Völk, M., & STROTZER, M. (2006) · Der Radiologe · doi:10.1007/s00117-005-1333-8 · Cited by 10
Assessment of Early Radiation Effects on the Liver
Masui, T., Yan, H., Kosugi, I., Sakamoto, S., Nishimura, T., Takahashi, M., Kaneko, M., & Fritz‐Zieroth, B. (1996) · Acta Radiologica · doi:10.1177/02841851960373p249 · Cited by 9
Effect of Superparamagnetic Iron Oxide Nanoparticles-Labeling on Mouse Embryonic Stem Cells.
Parsa, H., Shamsasenjan, K., Movassaghpour, A. A., Akbarzadeh, P., Tabrizi, B. A., Dehdilani, N., Lotfinegad, P., & Soleimanloo, F. (2015) · PubMed Central · doi:10.22074/cellj.2016.3719 · Cited by 9
Murakami, T., Kim, T., Takamura, M., Shimizu, J., Hori, M., Dono, K., Takachi, K., Kato, N., Miyazawa, T., Sakon, M., et al. (2001) · Digestive Diseases and Sciences · doi:10.1023/a:1005585101620 · Cited by 9
Kakite, S., Fujii, S., Nakamatsu, S., Kanasaki, Y., Yamashita, E., Matsusue, E., Ouchi, Y., Kaminou, T., Tokunaga, S., Koda, M., et al. (2011) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.01.048 · Cited by 8
Lüdemann, L., Schmitt, B., Podrabsky, P., Schnackenburg, B., Böck, J. C., & Gutberlet, M. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.12.002 · Cited by 8
Krishnan, K. M. (2010) · Cited by 8
The Extracellular Matrix as a Target for Biophysical and Molecular Magnetic Resonance Imaging
de Schellenberger, A. A., Bergs, J. W. J., Sack, I., & Taupitz, M. (2018) · Springer eBooks · doi:10.1007/978-3-319-65924-4_6 · Cited by 11
Fukukura, Y., Kamiyama, T., Takumi, K., Shindo, T., Higashi, R., & Nakajo, M. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22098 · Cited by 8
Thomas, R. G., Kim, S., Tran, T.-A.-T., Kim, Y. H., Nagareddy, R., Jung, T., Kim, S. K., & Jeong, Y. Y. (2024) · Nanomaterials · doi:10.3390/nano14110939 · Cited by 8
Implications of Nanotechnology in Cancer Diagnostics and Therapeutics
Rai, N. K., Singh, S. K., Tiwari, M., & Sharma, L. K. (2020) · Nanotechnology in the life sciences · doi:10.1007/978-3-030-41464-1_12 · Cited by 7
Gerwing, M., Krähling, T., Schliemann, C., Harrach, S., Schwöppe, C., Berdel, A. F., Klein, S., Hartmann, W., Wardelmann, E., Heindel, W. L., et al. (2021) · Cancers · doi:10.3390/cancers13235880 · Cited by 7
Assessment of reperfusion injury by means of MR contrast agents in rat liver
Reimer, P., Allkemper, T., Bremer, C., Rummeny, E. J., Spiegel, H. U., Balzer, T., & Peters, P. E. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070307 · Cited by 7
Caramella, D., Jin, X.-N., Mascalchi, M., Agen, C., Petruzzi, P., Kresse, M., Bianucci, D., Ceretti, E., Semmler, W., & Bartolozzi, C. (1996) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf01772010 · Cited by 7
Doerfler, A., Forsting, M., Reith, W., Heiland, S., Weber, J., Hacke, W., & Sartor, K. J. (1997) · PubMed Central · Cited by 7
Mahfouz, A., & Hamm, B. (1997) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(21)00194-x · Cited by 7
Liu, Y., Meng, Y., Zhu, Y., Gu, L., Ma, A., Liu, R., Liu, D., Shen, S., Zhang, S., Xu, C., et al. (2024) · Regenerative Biomaterials · doi:10.1093/rb/rbae065 · Cited by 6
Higashihara, H., Murakami, T., Kim, T., Hori, M., Onishi, H., Nakata, S., Osuga, K., Tomoda, K., & Nakamura, H. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.09.028 · Cited by 6
Balzer, T., Carter, E. C., Shamsi, K., & Niendort, H.-P. (1996) · Academic Radiology · doi:10.1016/s1076-6332(96)80603-9 · Cited by 6
Hydrogels-Based Drug Delivery System with Molecular Imaging
Oh, K. S., & Yuk, S. H. (2010) · Springer eBooks · doi:10.1007/978-1-4419-5919-5_10 · Cited by 5
Raabe, N., Forberich, E., Freund, B., Bruns†, O. T., Heine, M., Kaul, M. G., Tromsdorf, U. I., Herich, L., Nielsen, P., Reimer, R., et al. (2014) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.1612 · Cited by 5
Anjali, Jha, S. K., & Kuanr, B. K. (2017) · AIP conference proceedings · doi:10.1063/1.4980343 · Cited by 5
Park, Y., Choi, D., Kim, S. H., Kim, S. H., Kim, M. J., Lee, J., Lim, J. H., Lee, W. J., & Lim, H. K. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.06.018 · Cited by 5
Gitsioudis, G., Fortner, P., Stuber, M., Missiou, A., André, F., Müller, O. J., Katus, H. A., & Korosoglou, G. (2016) · International journal of cardiac imaging · doi:10.1007/s10554-016-0955-4 · Cited by 5
Ferucarbotran versus Gd-DTPA-enhanced MR imaging in the detection of focal hepatic lesions
Wei-zhong, C. (2007) · World Journal of Gastroenterology · doi:10.3748/wjg.v13.i36.4891 · Cited by 5
Hori, M., Murakami, T., Kim, T., Iannaccone, R., Abe, H., Onishi, H., Tomoda, K., Catalano, C., Passariello, R., & Nakamura, H. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20542 · Cited by 5
Furuta, T., Yamaguchi, M., Nakagami, R., Akahane, M., Minami, M., Ohtomo, K., & Fujii, H. (2014) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-014-0434-7 · Cited by 4
Gitsioudis, G., Stuber, M., Arend, I., Thomas, M., Yu, J., Hilbel, T., Giannitsis, E., Katus, H. A., & Korosoglou, G. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24043 · Cited by 4
Magnetic Particle Imaging: Kinetics of the intravascular signal in vivo
Haegele, J., Duschka, R. L., Graeser, M., Luedtke-Buzug, K., Schaecke, C., Panagiotopoulos, N., Buzug, T. M., Barkhausen, J., & VOGT, F. M. (2013) · International Workshop on Magnetic Particle Imaging · doi:10.1109/iwmpi.2013.6528350 · Cited by 4
Carbon-Based Nanomaterials for Targeted Drug and Gene Delivery Systems
Makwikwi, T., Kumar, G. V., Manicum, A.-L. E., Sekaran, S., & Katerere, D. R. (2022) · Nanotechnology in the life sciences · doi:10.1007/978-3-031-12658-1_16 · Cited by 4
Chou, C.-T., Chen, R., Chen, W.-T., & Lii, J.-M. (2008) · Clinical Radiology · doi:10.1016/j.crad.2008.07.010 · Cited by 4
Potential of Iron Oxide Nanoparticles as Drug Delivery Vehicle
Hassan, M. A., Khan, A. Z., Sajid, M. M., Javed, Y., Ullah, A., Shad, N. A., Sharma, S. K., Shafique, M. W., & Sarwar, M. (2021) · Topics in mining, metallurgy and materials engineering · doi:10.1007/978-3-030-79960-1_5 · Cited by 4
Hsiao, Y. P., Huang, C.-H., Lin, Y.-C., & Jan, T. (2019) · International Journal of Nanomedicine · doi:10.2147/ijn.s189327 · Cited by 4
Schmitz, S. A., Nikolova, A., O’Regan, D. P., Albrecht, T., Hohmann, J., & Wolf, K.-J. (2006) · Acta Radiologica · doi:10.1080/02841850600791518 · Cited by 3
Fast gradient echo MR imaging of the liver enhanced with superparamagnetic iron oxide
Fishbein, M. H., Long, F., & Smith, M. A. (1997) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(97)00019-2 · Cited by 3
Hammerstingl, R., Schwarz, W., Hochmuth, K., Staib-Sebler, E., Lorenz, M., & Vogl, T. J. (2001) · Der Radiologe · doi:10.1007/s001170050924 · Cited by 2
Semmler, W., Brix, G., Kolem, H., Nitz, W. R., Bock, M., Hauert, F., Fischer, H., NIENDORF, H. P., Balzer, T., & Reimer, P. (2002) · Springer eBooks · doi:10.1007/978-3-642-56044-6_2 · Cited by 2
Magnetic Resonance Imaging of Hepatocellular Carcinoma
Vogl, T. J., & Hammerstingl, R. (1999) · Medical radiology · doi:10.1007/978-3-642-58641-5_7 · Cited by 2
Looking into the future: iotrolan and beyond
Niendorf, H. P., Fritzsch, T., Herrschaft, G., Kŕause, W., Muffler, A., & Schürmann, R. (1995) · European Radiology · doi:10.1007/bf02343274 · Cited by 2
Ittrich, H., Peldschus, K., Raabe, N., Kaul, M. G., & Adam, G. (2013) · Cited by 1
Development and appraisal of MRI contrast agents for the in vivo analysis of stem cell grafts
Williams, S. (2012) · ORCA Online Research @Cardiff (Cardiff University) · Cited by 1
Magnetic Resonance Nanoparticle Probes for Cancer Imaging
Jun, Y., Jang, J.-T., & Cheon, J. (2003) · Nanotechnologies for the Life Sciences · doi:10.1002/9783527610419.ntls0075 · Cited by 1
Saito, K., Hashimoto, T., Kotake, F., Nakamura, H., Mizokami, Y., Shimokobe, K., & Abe, K. (2002) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.1.199 · Cited by 1
Murakami, T., Kim, T., Hori, M., Takamura, M., Tsuda, K., Takahashi, S., Narumi, Y., & Nakamura, H. (2000) · Acta Radiologica · doi:10.1034/j.1600-0455.2000.041003263.x · Cited by 1
Nanotechnological Applications in Cancer Treatment and Tumor Imaging
Erdoğan, A., & Özkan, A. (2013) · DergiPark (Istanbul University)
Völk, M., Schlottmann, K., & STROTZER, M. (2007) · Springer eBooks · doi:10.1007/978-3-540-68472-5_9
Yang, H., Xu, Y., Wu, Y., Liu, W., Lü, G.-S., & Cao, G.-H. (2008) · Chinese Journal of Cancer Research · doi:10.1007/s11670-008-0026-z
Detection of Portal Perfusion Abnormalities
Iwazawa, J., Nishida, N., Yamamoto, A., Nango, M., Ninoi, T., Murakami, Y., Nakamura, K. D., & Inoue, Y. (2006) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200603000-00001
Sugihara, S., Suto, Y., Kamba, M., & Yoshida, K. (1996) · Yonago acta medica
Surface chemical functionalization of magnetic nanoparticles
Bao, Y. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-21668-8.00005-5
Magnetresonanztomographie von Lebermetastasen — ein Überblick
Hammerstingl, R., Schwarz, W., & Vogl, T. J. (2002) · Springer eBooks · doi:10.1007/978-3-642-59385-7_9
Additional file 1 of Magnetic core–shell nanowires as MRI contrast agents for cell tracking
Martínez-Banderas, A. I., Aires, A., Plaza‐García, S., Colás, L., Moreno, J. A., Ravasi, T., Merzaban, J. S., Ramos‐Cabrer, P., Cortajarena, A. L., & Kosel, J. (2020) · Figshare · doi:10.6084/m9.figshare.11979390
Magnetic Resonance Contrast Agents of Increased Specificity
Weinmann, H. (1999) · Medical radiology · doi:10.1007/978-3-642-59814-2_17
Metadata
- Authors
- Hamm, B., Staks, T., Taupitz, M., Maibauer, R., Speidel, A., Huppertz, A., Frenzel, T., Lawaczeck, R., Wolf, K. J., & Lange, L.
- Affiliations
- Humboldt-Universität zu Berlin (DE)
- Freie Universität Berlin (DE)
- Corresponding author
- Hamm, Bernd
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 4
- Issue
- 5
- Pages
- 659-668
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2163391474
- Cited by
- 187
- References
- 25
- Citations by year
- 2024: 5 · 2023: 2 · 2022: 2 · 2021: 5 · 2020: 7 · 2019: 6 · 2018: 4 · 2017: 3 · 2016: 4 · 2015: 5 · 2014: 10 · 2013: 15 · 2012: 5
- FWCI
- 8.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Magnetic Resonance Imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Physical Sciences › Materials Science › Materials Chemistry › Lanthanide and Transition Metal Complexes
- Keywords
- superparamagnetic iron oxide nanoparticles, MRI contrast agents, liver imaging, spleen imaging, contrast-enhanced MRI, safety and tolerability, activated partial thromboplastin time
- MeSH terms
- Adult, Contrast Media, Dextrans, Dose-Response Relationship, Drug, Drug Tolerance, Humans, Image Enhancement, Injections, Intravenous, Iron, Liver, Magnetic Resonance Imaging, Male, Oxides, Partial Thromboplastin Time, Placebos, Prospective Studies, Spleen, Suspensions, Single-Blind Method, Ferrosoferric Oxide, Magnetite Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review