The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Contrast-enhanced MR imaging of liver and spleen: first experience in humans with a new superparamagnetic iron oxide
Abstract
The aim of this prospective study was to obtain the first human safety and magnetic resonance (MR) imaging results with a new formulation of superparamagnetic iron oxide (SPIO) (SHU 555 A). The SPIO was tested at four iron doses, from 5 to 40 mumol/kg. Laboratory tests and clinical measurements were done in 32 healthy volunteers for up to 3 weeks after administration. MR imaging at 1.5 T was performed before and 8 hours to 14 days after fast intravenous injection (500 mumol Fe/min) of the SPIO (six subjects per dose). Results of this phase I study demonstrate that SHU 555 A at a concentration of 0.5 mol Fe/L was well tolerated. A dose-dependent minor increase in activated partial thromboplastin time, which remained within the normal range, was seen. All doses of SPIO caused a signal loss in both liver and spleen (P < .05) with a spin-echo sequence (TR = 2,300 msec, TE = 45 msec). The signal losses in the liver 8 hours after contrast agent injection were 58%, 79%, 82%, and 87% for the 5, 10, 20, and 40 mumol Fe/kg doses, respectively. The corresponding signal losses in the spleen were 23%, 45%, 65%, and 78%, respectively. The doses that reduced signal intensity by half were 3.1 mumol Fe/kg for the liver and 12.8 mumol Fe/kg for the spleen. The results suggest that the new SPIO formulation is a safe and efficient MR contrast agent.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A clinical study assessing the toxicity of ferumcarbotran reported adverse effects such as irritation at the site of injection, pain and headache, which were all only observed in a small subset of individuals [134].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [134]
Citations
Cites
Superparamagnetic iron oxide: pharmacokinetics and toxicity
Weissleder, R., Stark, D., Engelstad, B. L., Bacon, B., Compton, C. C., White, D., Jacobs, P. M., & Lewis, J. M. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.1.167 · Cited by 1,045
Weissleder, R., Elizondo, G., WITTENBERG, J., Rabito, C. A., Bengele, H. H., & Josephson, L. (1990) · Radiology · doi:10.1148/radiology.175.2.2326474 · Cited by 1,027
Superparamagnetic iron oxide: clinical application as a contrast agent for MR imaging of the liver.
Stark, D. D., Weissleder, R., Elizondo, G., Hahn, P. F., Saini, S., Todd, L. E., WITTENBERG, J., & Ferrucci, J. T. (1988) · Radiology · doi:10.1148/radiology.168.2.3393649 · Cited by 512
Book of Abstracts, Society of Magnetic Resonance in Medicine
Tanttu, J. I., & SEPPONEN, R. E. (1993) · Cited by 394
Heiken, J. P., Weyman, P. J., Lee, J. K., Balfe, D. M., Picus, D. D., Brunt, E. M., & Flye, M. W. (1989) · Radiology · doi:10.1148/radiology.171.1.2538862 · Cited by 312
Iron oxide-enhanced MR imaging of the liver and spleen: review of the first 5 years
Ferrucci, J. T., & Stark, D. D. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.155.5.2120963 · Cited by 279
Nelson, R. C., CHEZMAR, J. L., Sugarbaker, P. H., & Bernardino, M. E. (1989) · Radiology · doi:10.1148/radiology.172.1.2662254 · Cited by 248
Focal liver lesions: MR imaging with Mn-DPDP--initial clinical results in 40 patients.
Hamm, B., Vogl, T. J., Branding, G., Schnell, B., Taupitz, M., Wolf, K. J., & Lissner, J. (1992) · Radiology · doi:10.1148/radiology.182.1.1309218 · Cited by 173
Semelka, R. C., Shoenut, J. P., Kroeker, M. A., Greenberg, H. M., Simm, F. C., Minuk, G. Y., Kroeker, R. M., & Micflikier, A. B. (1992) · Radiology · doi:10.1148/radiology.184.3.1324509 · Cited by 166
Hepatic metastases: randomized, controlled comparison of detection with MR imaging and CT.
Stark, D. D., WITTENBERG, J., Butch, R. J., & Ferrucci, J. T. (1987) · Radiology · doi:10.1148/radiology.165.2.3310094 · Cited by 150
Research works printed but not linked: 2
- Harker LA, 1991, Future directions, Semin Hematol, 28, 73
- World Health Organization, 1989, Radiocontrast media: labelling changes, FDA Drug Bull, 19, 138
Cited by
Sorted by citations
Ulbrich, K., Holá, K., Šubr, V., Bakandritsos, A., Tuček, J., & Zbořil, R. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00589 · Cited by 1,759
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181
Biomedical Nanomagnetics: A Spin Through Possibilities in Imaging, Diagnostics, and Therapy
Krishnan, K. M. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2046907 · Cited by 850
Application of Nanotechnology in Cancer Therapy and Imaging
Wang, X., Yang, L., Chen, Z., & Shin, D. M. (2008) · CA A Cancer Journal for Clinicians · doi:10.3322/ca.2007.0003 · Cited by 704
Reimer, P., & Balzer, T. (2003) · European Radiology · doi:10.1007/s00330-002-1721-7 · Cited by 614
Metadata
- Authors
- Hamm, B., Staks, T., Taupitz, M., Maibauer, R., Speidel, A., Huppertz, A., Frenzel, T., Lawaczeck, R., Wolf, K. J., & Lange, L.
- Affiliations
- Humboldt-Universität zu Berlin (DE)
- Freie Universität Berlin (DE)
- Corresponding author
- Hamm, Bernd
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 4
- Issue
- 5
- Pages
- 659-668
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2163391474
- Cited by
- 187
- References
- 25
- Citations by year
- 2024: 5 · 2023: 2 · 2022: 2 · 2021: 5 · 2020: 7 · 2019: 6 · 2018: 4 · 2017: 3 · 2016: 4 · 2015: 5 · 2014: 10 · 2013: 15 · 2012: 5
- FWCI
- 8.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Magnetic Resonance Imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Physical Sciences › Materials Science › Materials Chemistry › Lanthanide and Transition Metal Complexes
- Keywords
- superparamagnetic iron oxide nanoparticles, MRI contrast agents, liver imaging, spleen imaging, contrast-enhanced MRI, safety and tolerability, activated partial thromboplastin time
- MeSH terms
- Adult, Contrast Media, Dextrans, Dose-Response Relationship, Drug, Drug Tolerance, Humans, Image Enhancement, Injections, Intravenous, Iron, Liver, Magnetic Resonance Imaging, Male, Oxides, Partial Thromboplastin Time, Placebos, Prospective Studies, Spleen, Suspensions, Single-Blind Method, Ferrosoferric Oxide, Magnetite Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review