Ferucarbotran (Resovist): a new clinically approved RES-specific contrast agent for contrast-enhanced MRI of the liver: properties, clinical development, and applications
Abstract
Ferucarbotran (Resovist) is the second clinically approved superparamagnetic iron oxide developed for contrast-enhanced MRI of the liver. The purpose of this review is to provide an overview on the properties, clinical development, and application of ferucarbotran. Safety data obtained during clinical phases I-III revealed a total of 162 adverse events within 1053 patients, of which 75 were classified as possibly, probably, or definitely drug related. The majority of events occurred within the first 3 h (73 of 75) and was of mild intensity. The agent significantly improves the detection of hypovascular focal liver lesions with a comparable sensitivity in lesion detection to CTAP but without a relevant loss in specificity. Furthermore, ferucarbotran leads to a significant improvement of the sensitivity for lesion classification and characterization of the most frequent liver lesions. Contrast-enhanced MRA is not feasible and the angiographic effect is not sufficient to allow for postprocessing of data into maximum intensity projections. Intraindividual studies at low-field (0.2 T) and high-field (1.5 T) showed similar rates for lesion detection. The time window for contrast-enhanced MRI of the liver is at least 1 day up to 4 days. The compound can be regarded as safe and well tolerated. Even bolus injections caused no cardiovascular side effects, lumbar back pain, or clinically relevant laboratory changes. The examination time can be kept short with T1- and T2-weighted pre-contrast sequences, dynamic MRI over 10 min, and finally accumulation phase T2-weighted MRI. Patients who may benefit in particular are surgical candidates for resection, transplantation, or interventional therapies, and patients with liver cirrhosis and/or suspected hepatocellular carcinoma to either exclude malignancy or to define the extent of disease, the location of lesions, and the type of newly detected lesions.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Ferucarbotran and ferumoxide have been available on the market and under clinical investigation.
“Available on the market and under clinical investigation have been ferucarbotran (Resovist®) and ferumoxide (Feridex® (USA), Endorem® (EU); see Table 1 [146, 147].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [147]
Cites
Encyclopedia of nuclear magnetic resonance
(2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)00914-2 · Cited by 1,656 · see citing works
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381 · see citing works
Superparamagnetic iron oxide: pharmacokinetics and toxicity
Weissleder, R., Stark, D., Engelstad, B. L., Bacon, B., Compton, C. C., White, D., Jacobs, P. M., & Lewis, J. M. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.1.167 · Cited by 1,045 · see citing works
Bassett, M. L., Halliday, J. W., & Powell, L. W. (1986) · Hepatology · doi:10.1002/hep.1840060106 · Cited by 673 · see citing works
Tumor interactions with the vasculature: angiogenesis and tumor metastasis
Blood, C. H. (1990) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/0304-419x(90)90014-r · Cited by 595 · see citing works
Superparamagnetic iron oxide: clinical application as a contrast agent for MR imaging of the liver.
Stark, D. D., Weissleder, R., Elizondo, G., Hahn, P. F., Saini, S., Todd, L. E., WITTENBERG, J., & Ferrucci, J. T. (1988) · Radiology · doi:10.1148/radiology.168.2.3393649 · Cited by 512 · see citing works
Long-circulating iron oxides for MR imaging
Weissleder, R., Bogdanov, A. A., Jr., Neuwelt, E. A., & Papisov, M. I. (1995) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00033-4 · Cited by 399 · see citing works
Uptake of dextran‐coated monocrystalline iron oxides in tumor cells and macrophages
Moore, A., Weissleder, R., & Bogdanov, A. A., Jr. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070629 · Cited by 263 · see citing works
Assessing tumor angiogenesis using macromolecular MR imaging contrast media
Brasch, R. C., Pham, C. D., Shames, D. M., et al. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070110 · Cited by 254 · see citing works
Breath-hold, contrast-enhanced, three-dimensional MR angiography.
Leung, D. A., McKinnon, G. C., Davis, C. P., et al. (1996) · Radiology · doi:10.1148/radiology.200.2.8685359 · Cited by 227 · see citing works
The effects of iron oxides on proton relaxivity
Josephson, L., Lewis, J. M., Jacobs, P. M., Hahn, P. F., & Stark, D. D. (1988) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(88)90088-4 · Cited by 217 · see citing works
Phase I clinical evaluation of a new iron oxide MR contrast agent
McLachlan, S. J., Morris, M. R., Lucas, M. A., Fisco, R. A., Eakins, M. N., Fowler, D. R., Scheetz, R. B., & Olukotun, A. Y. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040313 · Cited by 194 · see citing works
Hepatic MRI with SPIO: detection and characterization of focal liver lesions
Reimer, P., & Tombach, B. (1998) · European Radiology · doi:10.1007/s003300050535 · Cited by 188 · see citing works
Self-citationReimer, P., Jähnke, N., Fiebich, M., Schima, W., Deckers, F., Marx, C., Holzknecht, N., & Saini, S. (2000) · Radiology · doi:10.1148/radiology.217.1.r00oc31152 · Cited by 188 · see citing works
Self-citationHamm, B., Staks, T., Taupitz, M., Maibauer, R., Speidel, A., Huppertz, A., Frenzel, T., Lawaczeck, R., Wolf, K. J., & Lange, L. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040508 · Cited by 187 · see citing works
Clinical results with Resovist: a phase 2 clinical trial.
Reimer, P., Rummeny, E., Daldrup-Link, H. E., Balzer, T., Tombach, B., Berns, T., & Peters, P. E. (1995) · Radiology · doi:10.1148/radiology.195.2.7724772 · Cited by 182 · see citing works
Self-citationRelationship Between Liver Size and Body Size
DeLand, F. H., & North, W. A. (1968) · Radiology · doi:10.1148/91.6.1195 · Cited by 163 · see citing works
Hulka, C. A., Edmister, W. B., Smith, B. L., et al. (1997) · Radiology · doi:10.1148/radiology.205.3.9393545 · Cited by 162 · see citing works
Rationale and applications for macromolecular Gd‐based contrast agents
Brasch, R. C. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220225 · Cited by 161 · see citing works
Allkemper, T., Bremer, C., Matuszewski, L., Ebert, W., & Reimer, P. (2002) · Radiology · doi:10.1148/radiol.2232010241 · Cited by 124 · see citing works
Self-citationBiodegradation of magnetite dextran nanoparticles in the rat. A histologic and biophysical study.
Okon, E. E., Pouliquen, D., Okon, P., et al. (1994) · PubMed · Cited by 118 · see citing works
Hepatic lesions: detection with ferumoxide-enhanced T1-weighted MR imaging.
Oudkerk, M., van den Heuvel, A. G., Wielopolski, P. A., et al. (1997) · Radiology · doi:10.1148/radiology.203.2.9114103 · Cited by 114 · see citing works
Lim, J. H., Choi, D., Cho, S. K., Kim, S. H., Lee, W. J., Lim, H. K., Park, C. K., Paik, S. W., & Kim, Y. I. (2001) · Radiology · doi:10.1148/radiol.2203001777 · Cited by 108 · see citing works
Saini, S., Edelman, R. R., Sharma, P. K., Li, W., Mayo-Smith, W. W., Slater, G. J., Eisenberg, P. J., & Hahn, P. F. (1995) · American Journal of Roentgenology · doi:10.2214/ajr.164.5.7717222 · Cited by 103 · see citing works
Liver MR imaging with iron oxides: toward consensus and clinical practice
Weissleder, R. (1994) · Radiology · doi:10.1148/radiology.193.3.7972790 · Cited by 101 · cited 6× · see citing works
“A variety of parenterally administered iron oxides have been developed for contrast-enhanced MR imaging of the liver [3].”
BackgroundInfluentialMagnetic Resonance Imaging of Focal Liver Lesions
Vogl, T. J., Hammerstingl, R., Schwarz, W., Kümmel, S., Müller, P., Balzer, T., Lauten, M., Balzer, J. O., Mack, M. G., Schimpfky, C., et al. (1996) · Investigative Radiology · doi:10.1097/00004424-199611000-00004 · Cited by 98 · see citing works
Self-citationAutomatic vessel segmentation using active contours in cine phase contrast flow measurements
Kozerke, S., Botnar, R. M., Oyre, S., Scheidegger, M. B., Pedersen, E. M., & Boesiger, P. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199907)10:1 · Cited by 98 · see citing works
MR imaging of the liver with Resovist: safety, efficacy, and pharmacodynamic properties.
Kopp, A. F., Laniado, M., Dammann, F., et al. (1997) · Radiology · doi:10.1148/radiology.204.3.9280254 · Cited by 95 · see citing works
Frank, H. A., Weissleder, R., & Brady, T. J. (1994) · American Journal of Roentgenology · doi:10.2214/ajr.162.1.8273667 · Cited by 88 · see citing works
Grandin, C. B. G., BEERS, B. E. V., Robert, A. R., Gigot, J., Geubel, A. P., & Pringot, J. (1995) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199505000-00014 · Cited by 78 · see citing works
Hahn, P. F., Stark, D. D., Weissleder, R., Elizondo, G., Saini, S., & Ferrucci, J. T. (1990) · Radiology · doi:10.1148/radiology.174.2.2296646 · Cited by 77 · see citing works
Grangier, C., Tourniaire, J., Mentha, G., Schiau, R., Howart, N., Chachuat, A., Grossholz, M., & Terrier, F. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199411000-00008 · Cited by 75 · see citing works
Harisinghani, M. G., Saini, S., Weissleder, R., Halpern, E. F., Schima, W., Rubin, D. L., Stillman, A. E., Sica, G. T., Small, W. C., & Hahn, P. F. (1997) · Radiology · doi:10.1148/radiology.202.3.9051017 · Cited by 66 · see citing works
Mergo, P. J., Helmberger, T. K., Nicolas, A. I., et al. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.2.8553952 · Cited by 57 · see citing works
Reimer, P., Marx, C., Rummeny, E. J., Müller, M., Lentschig, M. G., Balzer, T., Dietl, K., Sulkowski, U., Berns, T., Shamsi, K., et al. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070602 · Cited by 44 · see citing works
Self-citationMergo, P. J., Engelken, J. D., Helmberger, T. K., et al. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080511 · Cited by 38 · see citing works
Characterization of focal hepatic lesions with SPIO-enhanced MRI
Zheng, W. (2002) · World Journal of Gastroenterology · doi:10.3748/wjg.v8.i1.82 · Cited by 30 · see citing works
Gansbeke, D. V., Metens, T., Matos, C., et al. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070306 · Cited by 21 · see citing works
Deckers, F., Corthouts, B., Nackaerts, Y., et al. (1997) · European Radiology · doi:10.1007/s003300050222 · Cited by 13 · see citing works
Evaluation of the Time Window for Resovist-Enhanced T2-Weighted MRI of the Liver
Reimer, P., Müller, M., Marx, C., & Balzer, T. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80222-2 · Cited by 11 · see citing works
Self-citationMR Enhancement of Hepatoma by Superparamagnetic Iron Oxide (SPIO) Particles
Yamamoto, H., Yamashita, Y., Yoshimatsu, S., Baba, Y., & Takahashi, M. (1995) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199507000-00036 · Cited by 10 · see citing works
Bonk, R. T., Schmiedl, U. P., Yuan, C., Nelson, J. A., BLACK, C. D. V., & Ladd, D. L. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200006)11:6 · Cited by 10 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181 · see citing works
Characterization of aqueous dispersions of Fe3O4 nanoparticles and their biomedical applications
Cheng, F.-Y., Su, C.-H., Yang, Y.-S., Yeh, C.-S., Tsai, C.-Y., Wu, C.-L., Wu, M.-T., & Shieh, D.-B. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.03.016 · Cited by 668 · see citing works
Synthesis of phase-pure and monodisperse iron oxide nanoparticles by thermal decomposition
Hufschmid, R., Arami, H., Ferguson, R. M., Gonzales, M., Teeman, E., Brush, L. N., Browning, N. D., & Krishnan, K. M. (2015) · Nanoscale · doi:10.1039/c5nr01651g · Cited by 341 · see citing works
Zheng, B., von See, M. P., Yu, E., Gunel, B., Lu, K., Vazin, T., Schaffer, D. V., Goodwill, P. W., & Conolly, S. M. (2016) · Theranostics · doi:10.7150/thno.13728 · Cited by 322 · see citing works
Magnetic particle imaging: current developments and future directions
Panagiotopoulos, N., Vogt, F., Barkhausen, J., Buzug, T. M., Duschka, R. L., Lüdtke-Buzug, K., Ahlborg, M., Bringout, G., Debbeler, C., Gräser, M., et al. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s70488 · Cited by 289 · see citing works
Monodisperse magnetite nanoparticle tracers for in vivo magnetic particle imaging
Khandhar, A. P., Ferguson, R. M., Arami, H., & Krishnan, K. M. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.087 · Cited by 152 · see citing works
Clinical Safety and Diagnostic Value of the Gadolinium Chelate Gadoterate Meglumine (Gd-DOTA)
Herborn, C. U., Honold, E., Wolf, M., Kemper, J., Kinner, S., Adam, G., & Barkhausen, J. (2007) · Investigative Radiology · doi:10.1097/01.rli.0000248893.01067.e5 · Cited by 126 · see citing works
Hu, J., Qian, Y., Wang, X., Liu, T., & Liu, S. (2012) · Langmuir · doi:10.1021/la203992q · Cited by 124 · see citing works
Magnetic resonance imaging of pancreatic islets transplanted into the liver in humans
Saudek, F., Jirák, D., Girman, P., Herynek, V., Dezortová, M., Kříž, J., Peregrin, J., Berková, Z., Zacharovová, K., & Hájek, M. (2010) · Transplantation · doi:10.1097/tp.0b013e3181ffba5e · Cited by 115 · see citing works
Kratz, H., Taupitz, M., Ariza de Schellenberger, A., Kosch, O., Eberbeck, D., Wagner, S., Trahms, L., Hamm, B., & Schnorr, J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0190214 · Cited by 92 · see citing works
Design of superparamagnetic nanoparticles for magnetic particle imaging (MPI)
Du, Y., Lai, P., Leung, C., & Pong, P. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140918682 · Cited by 81 · see citing works
- Authors
- Reimer, P., & Balzer, T.
- Affiliations
- Städtisches Klinikum Karlsruhe (DE)
- Corresponding author
- Reimer, Peter
- ORCID
- Reimer, Peter
- Venue
- European Radiology
- Published
- 2003-06
- Volume
- 13
- Issue
- 6
- Pages
- 1266-1276
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W1560609297
- Cited by
- 614
- References
- 42
- Citations by year
- 2026: 10 · 2025: 25 · 2024: 26 · 2023: 29 · 2022: 33 · 2021: 31 · 2020: 37 · 2019: 26 · 2018: 35 · 2017: 34 · 2016: 29 · 2015: 35 · 2014: 42 · 2013: 30 · 2012: 28
- FWCI
- 13.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- European Radiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › MRI in cancer diagnosis
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Keywords
- ferucarbotran, Resovist, superparamagnetic iron oxide nanoparticles, contrast-enhanced MRI, hepatocellular carcinoma, liver lesion detection, drug safety, adverse events, liver cirrhosis, lesion characterization
- MeSH terms
- Contrast Media, Dextrans, Humans, Iron, Liver, Liver Diseases, Liver Neoplasms, Magnetic Resonance Imaging, Oxides, Safety, Time Factors, Multicenter Studies as Topic, Randomized Controlled Trials as Topic, Clinical Trials, Phase I as Topic, Clinical Trials, Phase II as Topic, Clinical Trials, Phase III as Topic, Magnetic Resonance Angiography, Ferrosoferric Oxide, Magnetite Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review