This study investigated the influence of slice thickness. section orientation, contrast, shape, and sequence type on the exactness of MRI‐based volumetry. Ni‐doped agarose gel phantoms (4 to 46 ml) were scanned with a T1‐weighted three‐dimensional Fourier transform (FT) fast low‐angle shot (FLASH) and a multiecho two‐dimensional FT‐Turbo spin‐echo (SE) sequence. After segmentation with a three‐dimensional region‐growing algorithm, the geometric volume was measured considering the partial volume effect. The variability coefficient (Pearson) was .7%. The volumetric error increased with slice thickness, depending on the size and form of the object. Cross sections resulted in smaller error than longitudinal sections (finger‐shaped phantoms, nonisotropic image data). Three‐dimensional FT was superior to two‐dimensional FT imaging. Results of slice thickness and section orientation experiments can be explained by the partial volume effect. Higher errors in two‐dimensional FT imaging were caused by object movements between two interleaved acquisitions. The study shows a considerable influence of the imaging parameters on the exactness, which depends on size and form of the structure of interest.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.1880060421

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Luft, A. R., Skalej, M., Welte, D., Kolb, R., & Klose, U.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
1996-07
Volume
6
Issue
4
Pages
700-704
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2089355124
Cited by
72
References
0
FWCI
4.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).