CoChat

Cine MR fourier velocimetry of blood flow through cardiac valves: Comparison with doppler echocardiography

Mohiaddin, Raad H., Gatehouse, Peter D., Henien, Michael, Firmin, David N. · 1997 · Journal of Magnetic Resonance Imaging
Cited by 51

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Noninvasive measurement of blood flow velocity through the cardiac valves has important clinical applications. A wide variety of MR methods are available for flow measurement. The aim of this study was to investigate the ability of cine MR Fourier velocimetry to measure flow through healthy cardiac valves and to compare MR and Doppler peak velocity measurements. Ten healthy volunteers (age mean ± SD, 24 ± 4 years) without history of valvular disease were studied. Four of the subjects were females. In each subject, aortic, pulmonary, mitral, and tricuspid valves were evaluated with MR and Doppler imaging. A whole‐body mobile MR machine was used, operating at .5‐T with actively shielded magnetic field gradient coils on all three axes capable of 20 mT/m at a slew rate of 60 mT/m/msec. The heart rate during MR and Doppler studies was not significantly different. The mean difference between the two studies was 2 beats/min, with a 95% confidence interval of −22 beats/min, +25 beats/min. Peak systolic flow velocity in the aortic and pulmonary valves and peak diastolic flow velocity in the mitral and tricuspid valves measured with MRI and Doppler echocardiography correlated well. The mean difference between the two measurements (MR — Doppler) was 63 mm/sec, with a 95% confidence interval of −180 mm/sec, +310 mm/sec. The agreement between two observers interpreting the same MR velocity maps was close. The mean difference between their two measurements was 23 mm/sec, with a 95% confidence interval of −20 mm/sec, +60 mm/sec. There was no significant difference between MR and Doppler imaging or between the two MR observers. MR Fourier velocimetry has the necessary ease, reliability, and speed to measure blood flow through the cardiac valves, although measurement of late diastolic flow in the atrioventricular valves is limited. Measurement of peak blood velocity through the cardiac valves by this method showed satisfactory agreement with Doppler, but its clinical application for assessing diseased cardiac valves must be established.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.1880070408

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Mohiaddin, R. H., Gatehouse, P. D., Henien, M., & Firmin, D. N.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
1997-07
Volume
7
Issue
4
Pages
657-663
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1973174057
Cited by
51
References
1
FWCI
2.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.