Cine MR fourier velocimetry of blood flow through cardiac valves: Comparison with doppler echocardiography
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Noninvasive measurement of blood flow velocity through the cardiac valves has important clinical applications. A wide variety of MR methods are available for flow measurement. The aim of this study was to investigate the ability of cine MR Fourier velocimetry to measure flow through healthy cardiac valves and to compare MR and Doppler peak velocity measurements. Ten healthy volunteers (age mean ± SD, 24 ± 4 years) without history of valvular disease were studied. Four of the subjects were females. In each subject, aortic, pulmonary, mitral, and tricuspid valves were evaluated with MR and Doppler imaging. A whole‐body mobile MR machine was used, operating at .5‐T with actively shielded magnetic field gradient coils on all three axes capable of 20 mT/m at a slew rate of 60 mT/m/msec. The heart rate during MR and Doppler studies was not significantly different. The mean difference between the two studies was 2 beats/min, with a 95% confidence interval of −22 beats/min, +25 beats/min. Peak systolic flow velocity in the aortic and pulmonary valves and peak diastolic flow velocity in the mitral and tricuspid valves measured with MRI and Doppler echocardiography correlated well. The mean difference between the two measurements (MR — Doppler) was 63 mm/sec, with a 95% confidence interval of −180 mm/sec, +310 mm/sec. The agreement between two observers interpreting the same MR velocity maps was close. The mean difference between their two measurements was 23 mm/sec, with a 95% confidence interval of −20 mm/sec, +60 mm/sec. There was no significant difference between MR and Doppler imaging or between the two MR observers. MR Fourier velocimetry has the necessary ease, reliability, and speed to measure blood flow through the cardiac valves, although measurement of late diastolic flow in the atrioventricular valves is limited. Measurement of peak blood velocity through the cardiac valves by this method showed satisfactory agreement with Doppler, but its clinical application for assessing diseased cardiac valves must be established.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
Lotz, J., Meier, C., Leppert, A., & Galanski, M. (2002) · RadioGraphics · doi:10.1148/radiographics.22.3.g02ma11651 · Cited by 673
Markl, M., Kilner, P. J., & Ebbers, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-7 · Cited by 463
Evaluation of left ventricular diastolic function with cardiac MR imaging.
Caudron, J., Fares, J., Bauer, F., & Dacher, J.-N. (2011) · Radiographics · doi:10.1148/rg.311105049 · Cited by 129
Woldendorp, K., Bannon, P. G., & Grieve, S. M. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00633-z · Cited by 32
Cardiac Magnetic Resonance Imaging for the Evaluation of Ventricular Function
Sarwar, A., Shapiro, M. D., Abbara, S., & Cury, R. C. (2008) · Seminars in Roentgenology · doi:10.1053/j.ro.2008.02.004 · Cited by 26
Metadata
- Authors
- Mohiaddin, R. H., Gatehouse, P. D., Henien, M., & Firmin, D. N.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1997-07
- Volume
- 7
- Issue
- 4
- Pages
- 657-663
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1973174057
- Cited by
- 51
- References
- 1
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.