The DOI matches its Crossref record.
Understanding pulsed magnetization transfer
Abstract
Using a two‐pool exchange model of magnetization transfer (MT), numeric simulations were developed to predict the time dependence of longitudinal magnetization in both semisolid and liquid pools for arbitrary pulsed radiofrequency (RF) irradiation. Whereas RF excitation of the liquid pool was modeled using the time‐dependent Bloch equations, RF saturation of the semi‐solid pool was described by a time‐dependent rate proportional to both the absorption lineshape of the semisolid pool and the square of the RF pulse amplitude. Simulations show good agreement with experimental results for a 4% agar gel aqueous system in which the two‐pool kinetics have been well studied previously. These simulations provide a method for interpreting pulsed MT effects, are easily extended to biologic tissues, and provide a basis for optimizing clinical imaging applications that exploit MT contrast.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Magnetization transfer in MRI: a review
Henkelman, R. M., Stanisz, G. J., & Graham, S. J. (2001) · NMR in Biomedicine · doi:10.1002/nbm.683 · Cited by 921
Self-citationAlternatives to Gadolinium-Based Metal Chelates for Magnetic Resonance Imaging
Viswanathan, S., Kovacs, Z., Green, K. N., Ratnakar, S. J., & Sherry, A. D. (2010) · Chemical Reviews · doi:10.1021/cr900284a · Cited by 439
Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI
Sled, J. G., & Pike, G. B. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1278 · Cited by 419
The current state-of-the-art of spinal cord imaging: Methods
Stroman, P. W., Wheeler-Kingshott, C., Bacon, M., Schwab, J. M., Bosma, R., Brooks, J., Cadotte, D., Carlstedt, T., Ciccarelli, O., Cohen-Adad, J., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.124 · Cited by 334
Helms, G., Dathe, H., Kallenberg, K., & Dechent, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21732 · Cited by 332
Heterogeneity in age-related white matter changes
Schmidt, R., Schmidt, H., Haybaeck, J., Loitfelder, M., Weis, S., Cavalieri, M., Seiler, S., Enzinger, C., Ropele, S., Erkinjuntti, T., et al. (2011) · Acta Neuropathologica · doi:10.1007/s00401-011-0851-x · Cited by 328
Gelman, N., Ewing, J. R., Gorell, J. M., Spickler, E. M., & Solomon, E. G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200101)45:1<71::aid-mrm1011>3.0.co;2-2 · Cited by 268
Metadata
- Authors
- Graham, S. J., & Henkelman, R. M.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1997-09
- Volume
- 7
- Issue
- 5
- Pages
- 903-912
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2004135386
- Cited by
- 159
- References
- 0
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.