Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 169

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Comparison of three methods for generating group statistical inferences from independent component analysis of functional magnetic resonance imaging data

Open access
Schmithorst, Vincent J., Holland, Scott K. · 2004 · Journal of Magnetic Resonance Imaging

Abstract

Purpose: To evaluate the relative effectiveness of three previously proposed methods of performing group independent component analysis (ICA) of functional magnetic resonance imaging (fMRI) data. Materials and Methods: Data were generated via computer simulation. Components were added to a varying number of subjects between 1 and 20, and intersubject variability was simulated for both the added sources and their associated time courses. Three methods of group ICA analyses were performed: across‐subject averaging, subject‐wise concatenation, and row‐wise concatenation (e.g., across time courses). Results: Concatenating across subjects provided the best overall performance in terms of accurate estimation of the sources and associated time courses. Averaging across subjects provided accurate estimation (R > 0.9) of the time courses when the sources were present in a sufficient fraction (about 15%) of 100 subjects. Concatenating across time courses was shown not to be a feasible method when unique sources were added to the data from each subject, simulating the effects of motion and susceptibility artifacts. Conclusion: Subject‐wise concatenation should be used when computationally feasible. For studies involving a large number of subjects, across‐subject averaging provides an acceptable alternative and reduces the computational load. J. Magn. Reson. Imaging 2004;19:365–368. © 2004 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.20009

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 169

Metadata

Authors
Schmithorst, V. J., & Holland, S. K.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2004-02-24
Volume
19
Issue
3
Pages
365-368
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1991432326
Cited by
169
References
2
FWCI
12.14
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of three methods for generating group statistical inferences from independent component analysis of functional magnetic resonance imaging data. https://app.cochat.ai/papers/10.1002/jmri.20009
The paper
Schmithorst, V. J., & Holland, S. K. (2004). Comparison of three methods for generating group statistical inferences from independent component analysis of functional magnetic resonance imaging data. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.20009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.