The DOI matches its Crossref record.
Correction of spatial distortion in EPI due to inhomogeneous static magnetic fields using the reversed gradient method
Open accessAbstract
Purpose: To derive and implement a method for correcting spatial distortion caused by in vivo inhomogeneous static magnetic fields in echo‐planar imaging (EPI). Materials and Methods: The reversed gradient method, which was initially devised to correct distortion in images generated by spin‐warp MRI, was adapted to correct distortion in EP images. This method provides point‐by‐point correction of distortion throughout the image. EP images, acquired with a 3 T MRI system, of a phantom and a volunteer's head were used to test the correction method. Results: Good correction was observed in all cases. Spatial distortion in the uncorrected images ranged up to 4 pixels (12 mm) and was corrected successfully. Conclusion: The correction was improved by the application of a nonlinear interpolation scheme. The correction requires that two EP images be acquired at each slice position. This increases the acquisition time, but an improved signal‐to‐noise ratio (SNR) is seen in the corrected image. The local SNR gain decreases with increasing distortion. In many EPI acquisition schemes, multiple images are averaged at each slice position to increase the SNR; in such cases the reversed gradient correction method can be applied with no increase in acquisition duration. J. Magn. Reson. Imaging 2004;19:499–507. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Andersson, J. L. R., & Sotiropoulos, S. N. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.019 · Cited by 3,500
Image processing and analysis methods for the Adolescent Brain Cognitive Development Study
Hagler, D. J., Hatton, S., Cornejo, M. D., Makowski, C., Fair, D. A., Dick, A. S., Sutherland, M. T., Casey, B. J., Barch, D. M., Harms, M. P., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116091 · Cited by 1,088
Twenty‐five pitfalls in the analysis of diffusion MRI data
Jones, D. K., & Cercignani, M. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1543 · Cited by 827
Holland, D., Kuperman, J. M., & Dale, A. M. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.044 · Cited by 471
Binney, R. J., Embleton, K. V., Jefferies, E., Parker, G. J. M., & Lambon Ralph, M. A. (2010) · Cerebral Cortex · doi:10.1093/cercor/bhq019 · Cited by 463
Radiotherapy planning using MRI
Schmidt, M. A., & Payne, G. S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/22/r323 · Cited by 357
Improving diffusion MRI using simultaneous multi-slice echo planar imaging
Setsompop, K., Cohen-Adad, J., Gagoski, B. A., Raij, T., Yendiki, A., Keil, B., Wedeen, V. J., & Wald, L. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.033 · Cited by 355
Hagler, D. J., Ahmadi, M. E., Kuperman, J., Holland, D., McDonald, C. R., Halgren, E., & Dale, A. M. (2009) · Human Brain Mapping · doi:10.1002/hbm.20619 · Cited by 293
White, N. S., McDonald, C. R., Farid, N., Kuperman, J., Karow, D., Schenker-Ahmed, N. M., Bartsch, H., Rakow-Penner, R., Holland, D., Shabaik, A., et al. (2014) · Cancer Research · doi:10.1158/0008-5472.can-13-3534 · Cited by 255
Cavanagh (2010) · doi:10.1016/j.neuropsychologia.2010.02.016 · Cited by 201
Juchem, C., Umesh Rudrapatna, S., Nixon, T. W., & de Graaf, R. A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.11.011 · Cited by 74
Kennis, M., van Rooij, S. J. H., Kahn, R. S., Geuze, E., & Leemans, A. (2016) · NeuroImage: Clinical · doi:10.1016/j.nicl.2016.03.022 · Cited by 18
Metadata
- Authors
- Morgan, P. S., Bowtell, R. W., McIntyre, D. J. O., & Worthington, B. S.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2004-03-29
- Volume
- 19
- Issue
- 4
- Pages
- 499-507
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1988529488
- Cited by
- 188
- References
- 0
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.