The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Radiotherapy planning using MRI
Open accessAbstract
The use of magnetic resonance imaging (MRI) in radiotherapy (RT) planning is rapidly expanding. We review the wide range of image contrast mechanisms available to MRI and the way they are exploited for RT planning. However a number of challenges are also considered: the requirements that MR images are acquired in the RT treatment position, that they are geometrically accurate, that effects of patient motion during the scan are minimized, that tissue markers are clearly demonstrated, that an estimate of electron density can be obtained. These issues are discussed in detail, prior to the consideration of a number of specific clinical applications. This is followed by a brief discussion on the development of real-time MRI-guided RT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Metal-Induced Artifacts in MRI
Hargreaves, B. A., Worters, P. W., Pauly, K. B., Pauly, J. M., Koch, K. M., & Gold, G. E. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.7364 · Cited by 559
New Fibrate Use and Acute Renal Outcomes in Elderly Adults: A Population-Based Study
Zhao, Y. Y., Weir, M. A., Manno, M., Cordy, P., Gomes, T., Hackam, D. G., Juurlink, D. N., Mamdani, M., Moist, L., Parikh, C. R., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-156-8-201204170-00401 · Cited by 258
Cited by
Molecularly Imprinted Polymers: Antibody Mimics for Bioimaging and Therapy
Haupt, K., Medina Rangel, P. X., & Bui, B. T. S. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00428 · Cited by 561
A review of multimodal image matching: Methods and applications
Jiang, X., Ma, J., Xiao, G., Shao, Z., & Guo, X. (2021) · Information Fusion · doi:10.1016/j.inffus.2021.02.012 · Cited by 532
Johnstone, E., Wyatt, J. J., Henry, A. M., Short, S. C., Sebag-Montefiore, D., Murray, L., Kelly, C. G., McCallum, H. M., & Speight, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.08.043 · Cited by 317
Survey on deep learning for radiotherapy
Meyer, P., Noblet, V., Mazzara, C., & Lallement, A. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.018 · Cited by 302
Maspero, M., Savenije, M. H. F., Dinkla, A. M., Seevinck, P. R., Intven, M. P. W., Jurgenliemk-Schulz, I. M., Kerkmeijer, L. G. W., & van den Berg, C. A. T. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aada6d · Cited by 253
Metadata
- Authors
- Schmidt, M. A., & Payne, G. S.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2015-10-28
- Volume
- 60
- Issue
- 22
- Pages
- R323-R361
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1859655790
- Cited by
- 357
- References
- 3
- FWCI
- 31.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiotherapy planning using MRI. https://app.cochat.ai/papers/10.1088/0031-9155/60/22/r323
- The paper
- Schmidt, M. A., & Payne, G. S. (2015). Radiotherapy planning using MRI. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/60/22/r323
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.