The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Analysis of myocardial perfusion MRI
Open accessAbstract
Rapid MR imaging (MRI) during the first pass of an injected tracer is used to assess myocardial perfusion with a spatial resolution of 2–3 mm, and to detect any regional impairments of myocardial blood flow (MBF) that may lead to ischemia. The spatial resolution is sufficient to detect flow reductions that are limited to the subendocardial layer. The capacity of the coronary system to increase MBF severalfold in response to vasodilation can be quantified by analysis of the myocardial contrast enhancement. The myocardial perfusion reserve (MPR) is a useful concept for quantifying the vasodilator response. The perfusion reserve can be estimated from the ratio of MBFs during vasodilation and at baseline, in units identical to those used for invasive measurements with labeled microspheres, or from dimensionless flow indices normalized by their value for autoregulated flow at rest. The perfusion reserve can be reduced as a result of a blunted hyperemic response and/or an abnormal resting blood flow. The absolute quantification of MBF removes uncertainties in the evaluation of the vasodilator response, and can be achieved without the use of complex tracer kinetic models; therefore, its application to clinical studies is feasible. J. Magn. Reson. Imaging 2004;19:758–770. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical Methods for the Solution of Ill-Posed Problems
Tikhonov, A. N., Goncharsky, A. V., Stepanov, V. V., & Yagola, A. G. (1995) · doi:10.1007/978-94-015-8480-7 · Cited by 1,819
Cited by
Kawel-Boehm, N., Hetzel, S. J., Ambale-Venkatesh, B., Captur, G., Francois, C. J., Jerosch-Herold, M., Salerno, M., Teague, S. D., Valsangiacomo-Buechel, E., van der Geest, R. J., et al. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00683-3 · Cited by 610
Self-citationClassic models for dynamic contrast‐enhanced MRI
Sourbron, S. P., & Buckley, D. L. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2940 · Cited by 434
Petersen, S. E., Jerosch-Herold, M., Hudsmith, L. E., Robson, M. D., Francis, J. M., Doll, H. A., Selvanayagam, J. B., Neubauer, S., & Watkins, H. (2007) · Circulation · doi:10.1161/circulationaha.106.657023 · Cited by 362
Self-citationPerfusion Magnetic Resonance Imaging: A Comprehensive Update on Principles and Techniques
Jahng, G.-H., Li, K.-L., Ostergaard, L., & Calamante, F. (2014) · Korean Journal of Radiology · doi:10.3348/kjr.2014.15.5.554 · Cited by 256
Coronary microvascular dysfunction
Sucato, V., Novo, G., Saladino, A., Evola, S., & Galassi, A. R. (2020) · Minerva Cardioangiologica · doi:10.23736/s0026-4725.20.05070-7 · Cited by 30
Metadata
- Authors
- Jerosch‐Herold, M., Seethamraju, R. T., Swingen, C. M., Wilke, N. M., & Stillman, A. E.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2004-05-24
- Volume
- 19
- Issue
- 6
- Pages
- 758-770
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1984296324
- Cited by
- 198
- References
- 1
- FWCI
- 12.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.