The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Differentiation of noncancerous tissue and cancer lesions by apparent diffusion coefficient values in transition and peripheral zones of the prostate
Abstract
Purpose: To compare the apparent diffusion coefficient (ADC) values of prostate cancer in both the peripheral zone (PZ) and the transition zone (TZ) with those of benign tissue in the same zone using echo‐planar diffusion weighted imaging with a parallel imaging technique. Materials and Methods: A total of 29 consecutive male patients (mean age 61.3 years, age range 53–88 years) with suspected prostate cancer were referred for MR imaging. All patients underwent transrectal ultrasound (TRUS)‐guided biopsy of the prostate after MR imaging at 1.5 T, including ADC. For each patient, seven to 10 specimens were obtained from the prostate, and regions of interest (ROIs) were drawn on the ADC map by referring to the urologist's illustration of TRUS‐guided biopsy sites. ADC values of cancerous tissue in both the PZ and TZ were compared to those of noncancerous tissue in the same zone. Results: Out of 29 patients, 23 had cancer tissue. In the 23 patients with cancer, the mean ADC value of all cancer ROIs and that of all noncancer ROIs, respectively, were 1.11 ± 0.41 × 10–3 and 1.68 ± 0.40 × 10–3 mm 2/second (values are mean ± SD) (P < 0.01). The mean ADC value of TZ cancer ROIs and that of TZ noncancer ROIs, respectively, were 1.13 ± 0.42 × 10–3 and 1.58 ± 0.37 × 10–3 mm 2/second (P < 0.01). Conclusions: ADC measurement with a parallel imaging technique showed that ADC values of prostate cancer in both the PZ and TZ were significantly lower than those of benign tissue in the PZ and TZ, respectively. J. Magn. Reson. Imaging 2005;21:258–262. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McNeal, J. E., Redwine, E. A., Freiha, F. S., & Stamey, T. A. (1988) · The American Journal of Surgical Pathology · doi:10.1097/00000478-198812000-00001 · Cited by 1,182
Quinn, M., & Babb, P. (2002) · BJU International · doi:10.1046/j.1464-410x.2002.2822.x · Cited by 446
Engelbrecht, M. R., Huisman, H. J., Laheij, R. J. F., Jager, G. J., van Leenders, G. J. L. H., Hulsbergen-Van De Kaa, C. A., de la Rosette, J. J. M. C. H., Blickman, J. G., & Barentsz, J. O. (2003) · Radiology · doi:10.1148/radiol.2291020200 · Cited by 380
Kurhanewicz, J. V., Swanson, M. G., Nelson, S. J., & Vigneron, D. B. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10172 · Cited by 351
Ichikawa, T., Haradome, H., Hachiya, J., Nitatori, T., & Araki, T. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.2.9456953 · Cited by 314
Apparent diffusion coefficients in the evaluation of high-grade cerebral gliomas.
Castillo, M., Smith, J. K., Kwock, L., & Wilber, K. P. (2001) · PubMed Central · Cited by 267
Issa, B. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10139 · Cited by 243
Jaermann, T., Crelier, G., Pruessmann, K. P., Golay, X., Netsch, T., van Muiswinkel, A. M. C., Mori, S., van Zijl, P. C. M., Valavanis, A., Kollias, S., et al. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10707 · Cited by 209
Gibbs, P., Tozer, D. J., Liney, G. P., & Turnbull, L. W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1298 · Cited by 199
Effects of cell volume fraction changes on apparent diffusion in human cells
Anderson, A. W., Xie, J., Pizzonia, J., Bronen, R. A., Spencer, D. D., & Gore, J. C. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00147-8 · Cited by 176
Dhingsa, R., Qayyum, A., Coakley, F. V., Lü, Y., Jones, K. D., Swanson, M. G., Carroll, P. R., Hricak, H., & Kurhanewicz, J. V. (2004) · Radiology · doi:10.1148/radiol.2301021562 · Cited by 90
Kiessling, F. M., Huber, P. E., Grobholz, R., Heilmann, M., Meding, J., Lichy, M. P., Fink, C., Krix, M., Peschke, P., & Schlemmer, H.-P. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000095472.37056.0b · Cited by 36
Cited by
Imaging Prostate Cancer: A Multidisciplinary Perspective
Hricak, H., Choyke, P. L., Eberhardt, S. C., Leibel, S. A., & Scardino, P. T. (2007) · Radiology · doi:10.1148/radiol.2431030580 · Cited by 601
Vargas, H. A., Akin, O., Franiel, T., Mazaheri, Y., Zheng, J., Moskowitz, C., Udo, K., Eastham, J., & Hricak, H. (2011) · Radiology · doi:10.1148/radiol.11102066 · Cited by 402
Fehr, D., Veeraraghavan, H., Wibmer, A., Gondo, T., Matsumoto, K., Vargas, H. A., Sala, E., Hricak, H., & Deasy, J. O. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1505935112 · Cited by 382
Technology Insight: water diffusion MRI—a potential new biomarker of response to cancer therapy
Patterson, D. M., Padhani, A. R., & Collins, D. J. (2008) · Nature Clinical Practice Oncology · doi:10.1038/ncponc1073 · Cited by 365
How Good is MRI at Detecting and Characterising Cancer within the Prostate?
Kirkham, A. P. S., Emberton, M., & Allen, C. (2006) · European Urology · doi:10.1016/j.eururo.2006.06.025 · Cited by 352
Metadata
- Authors
- Sato, C., Naganawa, S., Nakamura, T., Kumada, H., Miura, S., Takizawa, O., & Ishigaki, T.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2005-02-18
- Volume
- 21
- Issue
- 3
- Pages
- 258-262
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2033069053
- Cited by
- 323
- References
- 12
- FWCI
- 18.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.