The DOI matches its Crossref record.
Combined helium‐3/proton magnetic resonance imaging measurement of ventilated lung volumes in smokers compared to never‐smokers
Open accessAbstract
Purpose: To use a combination of helium‐3 (3‐He) magnetic resonance imaging (MRI) and proton single‐shot fast spin echo (SSFSE) to compare ventilated lung volumes in groups of “healthy” smokers, smokers diagnosed with moderate chronic obstructive pulmonary disease (COPD), and never‐smokers. Materials and Methods: All study participants were assessed with spirometry prior to imaging. 3‐He images were collected during an arrested breath hold, after inhaling a mixture of 200 mL of hyperpolarized 3‐He/800 mL of N 2. Proton SSFSE images were acquired after inhaling 1 liter of room air. The ventilated volume for each study participant was calculated from the 3‐He images, and a ratio was calculated to give a percentage ventilated lung volume. Results: Never‐smokers exhibited a 90% mean ventilated volume. The mean ventilated lung volumes for healthy smokers and smokers diagnosed with COPD were 75.2% and 67.6%, respectively. No correlation with spirometry was demonstrated for either of the smoking groups. Conclusion: Combined 3‐He/Proton SSFSE MRI of the lungs is a noninvasive method, using nonionizing radiation, which demonstrates ventilated airspaces and enables the calculation of ventilated lung volumes. This method appears to be sensitive to early obstructive changes in the lungs of smokers. J. Magn. Reson. Imaging 2005;21:365–369. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Spin Hyperpolarization in Modern Magnetic Resonance
Eills, J., Budker, D., Cavagnero, S., Chekmenev, E. Y., Elliott, S. J., Jannin, S., Lesage, A., Matysik, J., Meersmann, T., Prisner, T., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00534 · Cited by 368
Reinhardt, J. M., Ding, K., Cao, K., Christensen, G. E., Hoffman, E. A., & Bodas, S. V. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.03.007 · Cited by 322
Evaluation of Asthma With Hyperpolarized Helium-3 MRI
de Lange, E. E., Altes, T. A., Patrie, J. T., Gaare, J. D., Knake, J. J., Mugler, J. P., & Platts-Mills, T. A. (2006) · Chest · doi:10.1378/chest.130.4.1055 · Cited by 279
Experimental and quantitative imaging techniques in interstitial lung disease
Weatherley, N. D., Eaden, J. A., Stewart, N. J., Bartholmai, B. J., Swift, A. J., Bianchi, S. M., & Wild, J. M. (2019) · Thorax · doi:10.1136/thoraxjnl-2018-211779 · Cited by 87
Self-citationTibiletti, M., Eaden, J. A., Naish, J. H., Hughes, P. J. C., Waterton, J. C., Heaton, M. J., Chaudhuri, N., Skeoch, S., Bruce, I. N., Bianchi, S., et al. (2023) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2022.10.005 · Cited by 13
Self-citation
Metadata
- Authors
- Woodhouse, N., Wild, J. M., Paley, M. N. J., Fichele, S., Said, Z., Swift, A. J., & van Beek, E. J. R.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2005-03-18
- Volume
- 21
- Issue
- 4
- Pages
- 365-369
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2041755348
- Cited by
- 182
- References
- 0
- FWCI
- 5.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combined helium‐3/proton magnetic resonance imaging measurement of ventilated lung volumes in smokers compared to never‐smokers. https://app.cochat.ai/papers/10.1002/jmri.20290
- The paper
- Woodhouse, N., Wild, J. M., Paley, M. N. J., Fichele, S., Said, Z., Swift, A. J., & van Beek, E. J. R. (2005). Combined helium‐3/proton magnetic resonance imaging measurement of ventilated lung volumes in smokers compared to never‐smokers. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.20290
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.