The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Registration-based estimates of local lung tissue expansion compared to xenon CT measures of specific ventilation
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images
Hu, S., Hoffman, E. A., & Reinhardt, J. M. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.929615 · Cited by 940
Self-citationRegional distribution of inspired gas in the lung.
Milic-Emili, J., Henderson, J. A., Dolovich, M. B., Trop, D., & Kaneko, K. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.3.749 · Cited by 762
Christensen, G. E., & Johnson, H. J. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932742 · Cited by 636
Self-citationConsistent landmark and intensity-based image registration
Johnson, H. J., & Christensen, G. E. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009381 · Cited by 399
Self-citationMartin, R. F. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.1.100 · Cited by 241
Hoffman, E. A., Reinhardt, J. M., Sonka, M., Simon, B. A., Guo, J., Saba, O., Chon, D., Samrah, S., Shikata, H., Tschirren, J., et al. (2003) · Academic Radiology · doi:10.1016/s1076-6332(03)00330-1 · Cited by 186
Self-citationWoodhouse, N., Wild, J. M., Paley, M. N. J., Fichele, S., Said, Z., Swift, A. J., & van Beek, E. J. R. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20290 · Cited by 182
Distribution of pulmonary ventilation using Xe-enhanced computed tomography in prone and supine dogs
Marcucci, C., Nyhan, D. P., & Simon, B. A. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.421 · Cited by 139
Christensen, G. E., Song, J. H., Lü, W., Naqa, I. E., & Low, D. A. (2007) · Medical Physics · doi:10.1118/1.2731029 · Cited by 127
Self-citationEffect of body orientation on regional lung expansion in dog and sloth
Hoffman, E. A., & Ritman, E. L. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.2.481 · Cited by 119
Self-citation
Cited by
Galbán, C. J., Han, M. K., Boes, J. L., Chughtai, K. A., Meyer, C. R., Johnson, T. D., Galbán, S., Rehemtulla, A., Kazerooni, E. A., Martinez, F. J., et al. (2012) · Nature Medicine · doi:10.1038/nm.2971 · Cited by 813
Emerging Applications of Bedside 3D Printing in Plastic Surgery
Chae, M. P., Rozen, W. M., McMenamin, P. G., Findlay, M. W., Spychal, R. T., & Hunter-Smith, D. J. (2015) · Frontiers in Surgery · doi:10.3389/fsurg.2015.00025 · Cited by 377
MRF-Based Deformable Registration and Ventilation Estimation of Lung CT
Heinrich, H. P., Jenkinson, M., Brady, M., & Schnabel, J. A. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2246577 · Cited by 311
Four-dimensional deformable image registration using trajectory modeling
Castillo, E., Castillo, R., Martinez, J., Shenoy, M., & Guerrero, T. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/1/018 · Cited by 261
Nieman, G. F., Satalin, J., Andrews, P., Aiash, H., Habashi, N. M., & Gatto, L. A. (2017) · Intensive Care Medicine Experimental · doi:10.1186/s40635-017-0121-x · Cited by 143
Metadata
- Authors
- Reinhardt, J. M., Ding, K., Cao, K., Christensen, G. E., Hoffman, E. A., & Bodas, S. V.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2008-12
- Volume
- 12
- Issue
- 6
- Pages
- 752-763
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2035619816
- Cited by
- 322
- References
- 13
- FWCI
- 21.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Registration-based estimates of local lung tissue expansion compared to xenon CT measures of specific ventilation. https://app.cochat.ai/papers/10.1016/j.media.2008.03.007
- The paper
- Reinhardt, J. M., Ding, K., Cao, K., Christensen, G. E., Hoffman, E. A., & Bodas, S. V. (2008). Registration-based estimates of local lung tissue expansion compared to xenon CT measures of specific ventilation. Medical Image Analysis. https://doi.org/10.1016/j.media.2008.03.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.