The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Apparent diffusion coefficient measurements with diffusion‐weighted magnetic resonance imaging for evaluation of hepatic fibrosis
Open accessAbstract
Purpose: To evaluate the use of apparent diffusion coefficient (ADC) measurements based on diffusion‐weighted MRI (DWI) to assess stage of liver disease. Materials and Methods: A total of 31 patients who underwent both a liver biopsy and DWI and 132 patients who only underwent DWI were enrolled. Biopsy specimens were scored for fibrosis and necroinflammation according to the Knodell histology activity index (HAI). The 31 patients consisted of 21 patients with chronic hepatitis and 10 with cirrhosis (Child‐Pugh stage A in nine and stage B in one), and the 132 patients consisted of 56 patients with cirrhosis (Child‐Pugh stage A in 41, stage B in 10, and stage C in five), 42 with chronic hepatitis, and 34 with normal liver function. The ADCs in the liver parenchyma were measured using DWI with relatively low b factors (b = 0.01 and 128.01 seconds/mm 2) and were compared among the HAI scores and among patients with cirrhosis, chronic hepatitis, and normal liver function. Results: The ADCs decreased as the fibrosis score in the HAI increased, and the correlation was statistically significant (P < 0.0001). No relationship between the ADCs and the necroinflammation scores in the HAI was found. The ADCs decreased as the stage of liver disease progressed or as the Child‐Pugh stage progressed, and these relationships were statistically significant (P < 0.0001). Conclusion: ADC measurements are potentially useful for the evaluation of fibrosis staging in the liver. J. Magn. Reson. Imaging 2005;22:80–85. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Cited by
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
Liver Cirrhosis: Intravoxel Incoherent Motion MR Imaging—Pilot Study
Luciani, A., Vignaud, A., Cavet, M., Tran Van Nhieu, J., Mallat, A., Ruel, L., Laurent, A., Deux, J.-F., Brugieres, P., & Rahmouni, A. (2008) · Radiology · doi:10.1148/radiol.2493080080 · Cited by 612
Patel, J., Sigmund, E. E., Rusinek, H., Oei, M., Babb, J. S., & Taouli, B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22081 · Cited by 371
Huwart, L., Sempoux, C., Salameh, N., Jamart, J., Annet, L., Sinkus, R., Peeters, F., ter Beek, L. C., Horsmans, Y., & Van Beers, B. E. (2007) · Radiology · doi:10.1148/radiol.2452061673 · Cited by 365
Diffusion-weighted Imaging in the Abdomen and Pelvis: Concepts and Applications
Qayyum, A. (2009) · RadioGraphics · doi:10.1148/rg.296095521 · Cited by 355
Metadata
- Authors
- Koinuma, M., Ohashi, I., Hanafusa, K., & Shibuya, H.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2005-06-21
- Volume
- 22
- Issue
- 1
- Pages
- 80-85
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2056108089
- Cited by
- 218
- References
- 1
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.