The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Comparative study into the robustness of compartmental modeling and model‐free analysis in DCE‐MRI studies
Abstract
Purpose: To evaluate and compare the reproducibility of the preferred phenomenological parameter IAUC 60 (initial area under the time‐concentration curve [IAUC] defined over the first 60 seconds postenhancement) with the preferred modeling parameter (Ktrans), as derived using two simple models, in abdominal and cerebral data collected in typical Phase I clinical trial conditions. Materials and Methods: Dynamic contrast enhanced MRI (DCE‐MRI) time series were acquired at two imaging centers from a group of patients with abdominal tumors and a group with gliomas. At both imaging centers, precontrast T 1 was calculated using a variable flip angle three‐dimensional spoiled gradient echo acquisition that was used to quantify tissue contrast agent concentration, allowing voxelwise definition of summary DCE‐MRI parameters. Results: A comparison of reproducibility showed that there was no statistically significant difference in reproducibility between IAUC 60 and Ktrans, although there was a trend towards better reproducibility for Ktrans (P = 0.0782). The 95% confidence intervals (CIs) for individual changes showed that for IAUC 60 and Ktrans, changes in excess of 47% and 31%, respectively, are outside the range of normal variability. Conclusion: Although modeling is more complex and more computationally intensive than an IAUC parameterization, our data suggest this approach to be preferable to a model‐free approach since it provides greater physiological insight without a reduction in statistical power for Phase I/II clinical drug trials. J. Magn. Reson. Imaging 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Angiogenesis in cancer, vascular, rheumatoid and other disease
Folkman, J. (1995) · Nature Medicine · doi:10.1038/nm0195-27 · Cited by 7,627
Cited by
Parker, G. J. M., Roberts, C., Macdonald, A., Buonaccorsi, G. A., Cheung, S., Buckley, D. L., Jackson, A., Watson, Y., Davies, K., & Jayson, G. C. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21066 · Cited by 660
Self-citationDCE-MRI biomarkers in the clinical evaluation of antiangiogenic and vascular disrupting agents
O'Connor, J. P. B., Jackson, A., Parker, G. J. M., & Jayson, G. C. (2007) · British Journal of Cancer · doi:10.1038/sj.bjc.6603515 · Cited by 484
Self-citationYankeelov, T., & Gore, J. (2007) · Current Medical Imaging Reviews · doi:10.2174/157340507780619179 · Cited by 398
Shukla‐Dave, A., Obuchowski, N. A., Chenevert, T. L., Jambawalikar, S., Schwartz, L. H., Malyarenko, D., Huang, W., Noworolski, S. M., Young, R. J., Shiroishi, M. S., et al. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26518 · Cited by 389
Perfusion and vascular permeability: Basic concepts and measurement in DCE-CT and DCE-MRI
Cuenod, C. A., & Balvay, D. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.10.010 · Cited by 312
Metadata
- Authors
- Roberts, C., Issa, B., Stone, A., Jackson, A., Waterton, J. C., & Parker, G. J. M.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2006-02-27
- Volume
- 23
- Issue
- 4
- Pages
- 554-563
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2133390154
- Cited by
- 162
- References
- 1
- FWCI
- 9.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.