Range of ventricular dimensions and function by steady‐state free precession cine MRI in repaired tetralogy of Fallot: Right ventricular outflow tract patch vs. conduit repair
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Purpose: To characterize the range of biventricular size and function evaluated by steady‐state free precession (SSFP) cine magnetic resonance (MR) in a large cohort of patients with repaired tetralogy of Fallot (TOF), and to compare these measurements in those with a right ventricular outflow tract (RVOT) patch vs. a right ventricle‐to‐pulmonary artery (RV‐PA) conduit. Materials and Methods: Analysis of ventricular size and function in 300 consecutive examinations in patients with repaired TOF evaluated by SSFP cine MR. Results: Of the 300 examinations performed in 256 patients, 69% had undergone repair with a RVOT patch and 31% with a RV‐PA conduit. Compared to patients with RV‐PA conduit, those with a RVOT patch had significantly more pulmonary regurgitation (PR) (38 ± 17 vs. 23 ± 16%, P < 0.0001), larger indexed RV end‐diastolic volume (154 ± 53 vs. 133 ± 51 mL/m 2, P = 0.002), similar indexed end‐systolic volume (80 ± 39 vs. 74 ± 46 mL/m 2, P = 0.31), higher ejection fraction (EF) (50 ± 9 vs. 47 ± 12%, P = 0.037), and lower mass‐to‐volume ratio (0.29 ± 0.08 vs. 0.36 ± 0.13, P < 0.0001). Pulmonary regurgitation fraction correlated positively with RV end‐diastolic volume index in the RVOT patch group (r = 0.51, P < 0.0001) but not in the RV‐PA conduit. Conclusion: This study provides the range and distribution of biventricular size and function, and PR measured by MRI in a large contemporary cohort of patients with repaired TOF, and demonstrates important variations in RV mechanics between patients repaired with a RVOT patch and those with an RV‐PA conduit. J. Magn. Reson. Imaging 2007;26:934–940. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gatzoulis, M. A., Balaji, S., Webber, S. A., Siu, S. C., Hokanson, J. S., Poile, C., Rosenthal, M., Nakazawa, M., Moller, J. H., Gillette, P. C., et al. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02714-8 · Cited by 1,779
Geva, T., Sandweiss, B. M., Gauvreau, K., Lock, J. E., & Powell, A. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.10.045 · Cited by 620
Self-citationLong-term results after early primary repair of tetralogy of Fallot.
Bacha, E. A., Scheule, A. M., Zurakowski, D., Erickson, L. C., Hung, J., Lang, P., Mayer, J. E., del Nido, P. J., & Jonas, R. A. (2001) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2001.115156 · Cited by 240 · cited 1×
“ALTHOUGH SURVIVAL OF PATIENTS undergoing surgical repair of tetralogy of Fallot (TOF) has steadily improved over the past several decades, the majority of patients have residual hemodynamic abnormalities stemming from their surgery (1,2).”
BackgroundRight and left ventricular systolic function late after repair of tetralogy of Fallot.
Gatzoulis, M. A., Elliott, J. T., Guru, V., Siu, S. C., Warsi, M. A., Webb, G. D., Williams, W. G., Liu, P., & McLaughlin, P. R. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01241-8 · Cited by 108
Cited by
Geva, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-9 · Cited by 582
“PR fraction is calculated as retrograde flow volume divided by antegrade flow volume in the proximal MPA using ECG-gated, free-breathing cine phase contrast sequence obtained in the short-axis of the proximal MPA (Figure 15 and 16) [46].”
BackgroundMethodInfluentialSelf-citationKilner, P. J., Geva, T., Kaemmerer, H., Trindade, P. T., Schwitter, J., & Webb, G. D. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp586 · Cited by 429
Self-citationValente, A. M., Cook, S., Festa, P., Ko, H. H., Krishnamurthy, R., Taylor, A. M., Warnes, C. A., Kreutzer, J., & Geva, T. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.11.009 · Cited by 317
Self-citationMooij, C. F., de Wit, C. J., Graham, D. A., Powell, A. J., & Geva, T. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21407 · Cited by 297
Self-citationGeva, T., Gauvreau, K., Powell, A. J., Cecchin, F., Rhodes, J., Geva, J., & del Nido, P. (2010) · Circulation · doi:10.1161/circulationaha.110.951178 · Cited by 222
Self-citationPulmonary Valve Replacement in Tetralogy of Fallot: An Updated Meta-Analysis
Van den Eynde, J., Sá, M. P. B. O., Vervoort, D., Roever, L., Meyns, B., Budts, W., Gewillig, M., Ruhparwar, A., Zhigalov, K., & Weymann, A. (2022) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2020.11.040 · Cited by 62
How to Image Repaired Tetralogy of Fallot
Valente, A. M., & Geva, T. (2017) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.116.004270 · Cited by 44
Self-citation
Metadata
- Authors
- Samyn, M. M., Powell, A. J., Garg, R., Sena, L., & Geva, T.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2007-09-25
- Volume
- 26
- Issue
- 4
- Pages
- 934-940
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1991457417
- Cited by
- 71
- References
- 4
- FWCI
- 3.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.