Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 297

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Reproducibility of MRI measurements of right ventricular size and function in patients with normal and dilated ventricles

Open access
Mooij, Christiaan F., de Wit, Cornelis J., Graham, Dionne A., Powell, Andrew J., Geva, Tal·2008·Journal of Magnetic Resonance Imaging

Abstract

Purpose: To determine the inter‐ and intraobserver reproducibility of cardiac magnetic resonance (CMR)‐derived measurements of right ventricular (RV) mass, volume, and function in patients with normal and dilated ventricles. Materials and Methods: CMR studies of 60 patients in three groups were studied: a normal RV group (N = 20) and two groups with RV dilation—atrial septal defect (ASD) (N = 20) and repaired tetralogy of Fallot (TOF) (N = 20). Two independent observers analyzed each study on two separate occasions. Inter‐ and intraobserver reproducibility of biventricular mass, volume, ejection fraction (EF), and stroke volume (SV) measurements were calculated. Results: High intraclass correlation coefficients (ICC) were found for interobserver (ICC = 0.94–0.99) and intraobserver (ICC = 0.96–0.99) comparisons of RV and left ventricular (LV) mass, volume, and SV measurements. RV and LV EF measurements were less reproducible (ICC = 0.79–0.87). RV mass measurements were significantly less correlated than the respective LV measurements. Small but statistically significant differences in correlation were noted in RV measurements across groups. Conclusion: Except for RV mass, inter‐ and intraobserver reproducibility of RV size and function measurements is high and generally comparable to that in the LV in patients with both normal and dilated RV. J. Magn. Reson. Imaging 2008;28:67–73. © 2008 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.21407

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 297

Metadata

Authors
Mooij, C. F., de Wit, C. J., Graham, D. A., Powell, A. J., & Geva, T.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2008-06-25
Volume
28
Issue
1
Pages
67-73
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2025767996
Cited by
297
References
26
FWCI
10.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility of MRI measurements of right ventricular size and function in patients with normal and dilated ventricles. https://app.cochat.ai/papers/10.1002/jmri.21407
The paper
Mooij, C. F., de Wit, C. J., Graham, D. A., Powell, A. J., & Geva, T. (2008). Reproducibility of MRI measurements of right ventricular size and function in patients with normal and dilated ventricles. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21407

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.