The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Chronic hepatitis: Role of diffusion‐weighted imaging and diffusion tensor imaging for the diagnosis of liver fibrosis and inflammation
Abstract
Purpose: To determine the diagnostic performance of liver apparent diffusion coefficient (ADC) measured with conventional diffusion‐weighted imaging (CDI) and diffusion tensor imaging (DTI) for the diagnosis of liver fibrosis and inflammation. Materials and Methods: Breathhold single‐shot echo‐planar imaging CDI and DTI with b‐values of 0 and 500 second/mm 2 was performed in 31 patients with chronic liver disease and 13 normal volunteers. Liver biopsy was performed in all patients with liver disease with a median delay of two days from MRI. Fibrosis and inflammation were scored on a 5‐point scale (0–4). Liver ADCs obtained with CDI and DTI were compared between patients stratified by fibrosis stage and inflammation grade. Receiver operating characteristic (ROC) curve analyses were conducted to evaluate the utility of the ADC measures for prediction of fibrosis and inflammation. Results: Patients with liver fibrosis and inflammation had significantly lower liver ADC than subjects without fibrosis or inflammation with CDI and DTI. For prediction of fibrosis stage ≥ 1 and stage ≥ 2, area under the ROC curve (AUC) of 0.848 and 0.783, sensitivity of 88.5% to 73.7%, and specificity of 73.3% to 72.7% were obtained, for ADC ≤1.40 × 10–3 mm 2/second and ≤1.30 × 10–3 mm 2/second (using CDI), respectively. For prediction of inflammation grade ≥ 1, AUC of 0.825, sensitivity of 75.0%, and specificity of 78.6% were obtained using ADC ≤ 1.30 × 10–3 mm 2/second (using CDI). CDI performed better than DTI for diagnosis of fibrosis and inflammation. Conclusion: Liver ADC can be used to predict liver fibrosis and inflammation with acceptable sensitivity and specificity. J. Magn. Reson. Imaging 2008;28:89–95. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
Looking into the functional architecture of the brain with diffusion MRI.
Le Bihan, D. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1119 · Cited by 1,571
Cited by
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
Self-citationPatel, J., Sigmund, E. E., Rusinek, H., Oei, M., Babb, J. S., & Taouli, B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22081 · Cited by 371
Self-citationDiffusion-weighted Imaging in the Abdomen and Pelvis: Concepts and Applications
Qayyum, A. (2009) · RadioGraphics · doi:10.1148/rg.296095521 · Cited by 355
Self-citationLe Bihan, D., Ichikawa, S., & Motosugi, U. (2017) · Radiology · doi:10.1148/radiol.2017170025 · Cited by 102
Metadata
- Authors
- Taouli, B., Chouli, M., Martin, A. J., Qayyum, A., Coakley, F. V., & Vilgrain, V.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2008-06-25
- Volume
- 28
- Issue
- 1
- Pages
- 89-95
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1971019976
- Cited by
- 207
- References
- 2
- FWCI
- 10.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronic hepatitis: Role of diffusion‐weighted imaging and diffusion tensor imaging for the diagnosis of liver fibrosis and inflammation. https://app.cochat.ai/papers/10.1002/jmri.21227
- The paper
- Taouli, B., Chouli, M., Martin, A. J., Qayyum, A., Coakley, F. V., & Vilgrain, V. (2008). Chronic hepatitis: Role of diffusion‐weighted imaging and diffusion tensor imaging for the diagnosis of liver fibrosis and inflammation. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21227
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.