CoChat

High‐resolution 7T MRI of the human hippocampus in vivo

Open access
Thomas, Bradley P., Welch, E. Brian, Niederhauser, Blake D., Whetsell, William O., Anderson, Adam W., Gore, John C., Avison, Malcolm J., Creasy, Jeffrey L. · 2008 · Journal of Magnetic Resonance Imaging
Cited by 130

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Purpose: To describe an initial experience imaging the human hippocampus in vivo using a 7T magnetic resonance (MR) scanner and a protocol developed for very high field neuroimaging. Materials and Methods: Six normal subjects were scanned on a 7T whole body MR scanner equipped with a 16‐channel head coil. Sequences included a full field of view T1‐weighted 3D turbo field echo (T1W 3D TFE: time of acquisition (TA) = 08:58), T2*‐weighted 2D fast field echo (T2*W 2D FFE: TA = 05:20), and susceptibility‐weighted imaging (SWI: TA = 04:20). SWI data were postprocessed using a minimum intensity projection (minIP) algorithm. Total imaging time was 23 minutes. Results: T1W 3D TFE images with 700 μm isotropic voxels provided excellent anatomic depiction of macroscopic hippocampal structures. T2*W 2D FFE images with 0.5 mm in‐plane resolution and 2.5 mm slice thickness provided clear discrimination of the Cornu Ammonis and the compilation of adjacent sublayers of the hippocampus. SWI images (0.5 mm in‐plane resolution, 1.0 mm slice thickness) delineated microvenous anatomy of the hippocampus. Conclusion: In vivo 7T MR imaging can take advantage of higher signal‐to‐noise and novel contrast mechanisms to provide increased conspicuity of hippocampal anatomy. J. Magn. Reson. Imaging 2008;28:1266–1272. © 2008 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.21576

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 130

Metadata

Authors
Thomas, B. P., Welch, E. B., Niederhauser, B. D., Whetsell, W. O., Anderson, A. W., Gore, J. C., Avison, M. J., & Creasy, J. L.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2008-10-28
Volume
28
Issue
5
Pages
1266-1272
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1994945454
Cited by
130
References
1
FWCI
7.65
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High‐resolution 7T MRI of the human hippocampus in vivo. https://app.cochat.ai/papers/10.1002/jmri.21576
The paper
Thomas, B. P., Welch, E. B., Niederhauser, B. D., Whetsell, W. O., Anderson, A. W., Gore, J. C., Avison, M. J., & Creasy, J. L. (2008). High‐resolution 7T MRI of the human hippocampus in vivo. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21576

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.