Normal biventricular function, volumes, and mass in children aged 8 to 17 years
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Purpose: To assess normal values for biventricular function, volumes, and mass with current cardiovascular magnetic resonance (CMR) imaging sequences in children. Materials and Methods: Included in the study were 60 healthy children aged 8–17 years. A short axis set of contiguous slices was acquired with CMR imaging employing steady‐state free precession. Biventricular end‐diastolic volume (EDV), end‐systolic volume (ESV), ejection fraction (EF), and mass were determined. Uni‐ and multivariate linear regression analyses were performed to study the interrelation of age, gender, and body surface area (BSA) on biventricular volumes and mass. The coefficient of variation was calculated for intra‐ and interobserver variability. Results: EF did not differ between boys and girls (mean LV‐EF 69 ± (SD) 5%, mean RV‐EF 65 ± 5%). BSA had good (EDV, mass) and modest (ESV) correlation with biventricular measurements. Gender appeared a significant modifier of these relations, whereas age had no independent contribution. The intra‐ and interobserver coefficient of variation was in the range 2.1%–13.9% for biventricular EDV, ESV, and mass. Conclusion: This study reveals gender‐specific normative data for biventricular function, volumes, and mass in children age 8–17 years that can be used as reference data in the follow‐up of pediatric cardiac patients. J. Magn. Reson. Imaging 2009;29:552–559. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Lorenz, C., Walker, E., Morgan, V., Klein, S., & Graham, T. (1999) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976649909080829 · Cited by 717
Cited by
Normal values for cardiovascular magnetic resonance in adults and children
Kawel-Boehm, N., Maceira, A., Valsangiacomo-Buechel, E. R., Vogel-Claussen, J., Turkbey, E. B., Williams, R., Plein, S., Tee, M., Eng, J., & Bluemke, D. A. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0111-7 · Cited by 746
Kawel-Boehm, N., Hetzel, S. J., Ambale-Venkatesh, B., Captur, G., Francois, C. J., Jerosch-Herold, M., Salerno, M., Teague, S. D., Valsangiacomo-Buechel, E., van der Geest, R. J., et al. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00683-3 · Cited by 610
Fratz, S., Chung, T., Greil, G. F., Samyn, M. M., Taylor, A. M., Valsangiacomo Buechel, E. R., Yoo, S.-J., & Powell, A. J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-51 · Cited by 507
Kawut, S. M., Lima, J. A. C., Barr, R. G., Chahal, H., Jain, A., Tandri, H., Praestgaard, A., Bagiella, E., Kizer, J. R., Johnson, W. C., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.985515 · Cited by 390
SCMR Position Paper (2020) on clinical indications for cardiovascular magnetic resonance
Leiner, T., Bogaert, J., Friedrich, M. G., Mohiaddin, R., Muthurangu, V., Myerson, S., Powell, A. J., Raman, S. V., & Pennell, D. J. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00682-4 · Cited by 328
Metadata
- Authors
- Robbers‐Visser, D., Boersma, E., & Helbing, W. A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2009-02-25
- Volume
- 29
- Issue
- 3
- Pages
- 552-559
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2035078931
- Cited by
- 118
- References
- 2
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.