Resovist enhanced MR imaging of the liver: does quantitative assessment help in focal lesion classification and characterization?
Open accessAbstract
PURPOSE: To improve characterization of focal liver lesions by a prospective quantitative analysis of percentage signal intensity change, in dynamic and late phases after slow (0.5 mL/s) Resovist administration. MATERIALS AND METHODS: Seventy-three patients were submitted on clinical indication to MR examination with Resovist. Signal intensity of 92 detected focal lesions (5-80 mm) were measured with regions of interest and normalized to paravertebral muscle in arterial, portal, equilibrium and T1/T2 late phases, by two observers in conference. Five values of percentage variations per patient were obtained and statistically evaluated. RESULTS: The enhancement obtained on dynamic study is more suitable in hemangiomas and focal nodular hyperplasias than in adenomas and hepatocellular carcinomas. To discriminate benign versus malignant lesions on late-phase-T2-weighted images, a cutoff = -26%, allowed sensitivity and specificity values of 97.4% and 97.7%, respectively. Area under the receiver operating characteristic (ROC) curve was 0.99. To differentiate hemangioma versus all other focal liver lesions, on late-phase-T1-weighted images, a cutoff = +40% permitted sensitivity and specificity values of 90.5% and 98.0%, respectively. Area under the ROC curve was 0.98. CONCLUSION: Late phase quantitative evaluation after slow Resovist administration, allows to differentiate malignant from benign hepatic masses and hemangiomas from all the others focal liver lesions, on T2-/T1-weighted acquisitions, respectively. J
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
SPION-enhanced MRI is useful to discriminate between malignant neoplastic liver lesions, benign neoplastic liver lesions or hyperplastic liver lesions.
“SPION-enhanced MRI is useful to discriminate between malignant neoplastic liver lesions (e.g. HCC or metastasis), benign neoplastic liver lesions (e.g. adenoma or hemangioma) or hyperplastic liver lesions (e.g. focal nodular hyperplasia) [149].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [149]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Iron oxide-enhanced MR imaging of the liver and spleen: review of the first 5 years
Ferrucci, J. T., & Stark, D. D. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.155.5.2120963 · Cited by 279 · cited 3× · see citing works
“Classification of benign (1) versus malignant (0) lesions on T2-weighted images.”
BackgroundMethodHagspiel, K. D., Neidl, K., Eichenberger, A. C., Weder, W., & Marinček, B. (1995) · Radiology · doi:10.1148/radiology.196.2.7617863 · Cited by 250 · see citing works
Hepatic MRI with SPIO: detection and characterization of focal liver lesions
Reimer, P., & Tombach, B. (1998) · European Radiology · doi:10.1007/s003300050535 · Cited by 188 · see citing works
Reimer, P., Jähnke, N., Fiebich, M., Schima, W., Deckers, F., Marx, C., Holzknecht, N., & Saini, S. (2000) · Radiology · doi:10.1148/radiology.217.1.r00oc31152 · Cited by 188 · see citing works
Lee, S., Park, S. H., Kim, K. W., et al. (2007) · Radiology · doi:10.1148/radiol.2442061177 · Cited by 182 · see citing works
Tang, Y., Yamashita, Y., Arakawa, A., et al. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.172.6.10350287 · Cited by 151 · see citing works
Yamamoto, H., Yamashita, Y., Yoshimatsu, S., et al. (1995) · Radiology · doi:10.1148/radiology.195.1.7892448 · Cited by 118 · see citing works
Preoperative Detection of Malignant Hepatic Tumors
Kondo, H., Kanematsu, M., Hoshi, H., et al. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.4.1740947 · Cited by 69 · see citing works
Ward, J., Chen, F., Guthrie, J. A., Wilson, D. J., Lodge, J. P. A., Wyatt, J. I., & Robinson, P. J. (2000) · Radiology · doi:10.1148/radiology.214.1.r00ja21159 · Cited by 68 · see citing works
Poeckler-Schoeniger, C., Koepke, J., Gueckel, F., et al. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00180-5 · Cited by 60 · see citing works
Shamsi, K., Balzer, T., Saini, S., et al. (1998) · Radiology · doi:10.1148/radiology.206.2.9457187 · Cited by 58 · see citing works
Namkung, S., Zech, C. J., Helmberger, T. K., Reiser, M. F., & Schoenberg, S. O. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20873 · Cited by 54 · see citing works
Kehagias, D. T., Gouliamos, A. D., Smyrniotis, V. E., & Vlahos, L. J. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1224 · Cited by 54 · see citing works
Kim, Y. K., Kim, C. S., Kwak, H. S., et al. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20188 · Cited by 47 · see citing works
Chen, F., Ward, J., & Robinson, P. J. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00193-3 · Cited by 44 · see citing works
Grazioli, L., Morana, G., Kirchin, M. A., et al. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10289 · Cited by 43 · see citing works
Self-citationBEERS, B. E. V., Lacrosse, M., Jamart, J., et al. (1997) · American Journal of Roentgenology · doi:10.2214/ajr.168.3.9057521 · Cited by 39 · see citing works
Schnorr, J., Wagner, S., Abramjuk, C., Drees, R., Schink, T., Schellenberger, E. A., Pilgrimm, H., Hamm, B., & Taupitz, M. (2006) · Radiology · doi:10.1148/radiol.2393040884 · Cited by 32 · see citing works
Specificity of SPIO particles for characterization of liver hemangiomas using MRI
Montet, X., Lazeyras, F., Howarth, N., et al. (2003) · Abdominal Imaging · doi:10.1007/s00261-003-0092-0 · Cited by 29 · see citing works
Detection of Focal Liver Lesions with Superparamagnetic Iron Oxide
Halavaara, J. T., Lamminen, A., Bondestam, S., et al. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199411000-00009 · Cited by 27 · see citing works
Wersebe, A., Wiskirchen, J., Decker, U., Schick, F., Dietz, K., ller-Schimpfle, M. M., Claussen, C. D., & Pereira, P. L. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000188359.72928.0f · Cited by 22 · see citing works
Arbab, A. S., Ichikawa, T., Araki, T., Toyama, K., Nambu, A., Ohsawa, S., Kumagai, H., & Aikawa, Y. (2000) · Abdominal Imaging · doi:10.1007/s002619910035 · Cited by 22 · see citing works
Grazioli, L., Bondioni, M. P., Romanini, L., et al. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21644 · Cited by 2 · see citing works
Self-citationLarkman (2001) · doi:10.1002/1522-2586(200102)13:2
Flagged first, then by citations
Research works printed but not linked: 1
- Kanematsu M, Itoh K, Matsuo M, et al. Malignant hepatic tumor detection with ferumoxides-enhanced MR imaging with a 1.5-T system: comparison of four imaging pulse sequences. J Magn Reson Imaging 2001;13:249-257.
Cited by
Sorted by citations
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181 · see citing works
- Authors
- Santoro, L., Grazioli, L., Filippone, A., Grassedonio, E., Belli, G., & Colagrande, S.
- Affiliations
- Azienda Ospedaliero-Universitaria Careggi (IT)
- Azienda Socio Sanitaria Territoriale degli Spedali Civili di Brescia (IT)
- University of Chieti-Pescara (IT)
- Azienda Ospedaliera Universitaria Policlinico "Paolo Giaccone" di Palermo (IT)
- Corresponding author
- Colagrande, Stefano
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2009-10-23
- Volume
- 30
- Issue
- 5
- Pages
- 1012-1020
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1990916204
- Cited by
- 18
- References
- 24
- Citations by year
- 2024: 1 · 2023: 1 · 2022: 2 · 2021: 2 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2014: 1 · 2012: 2
- FWCI
- 1.51
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- Locations
- Journal of Magnetic Resonance Imaging (publishedVersion)
- PubMed (publishedVersion)
- Florence Research (University of Florence) (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › MRI in cancer diagnosis
- Health Sciences › Medicine › Hepatology › Hepatocellular Carcinoma Treatment and Prognosis
- Health Sciences › Medicine › Epidemiology › Liver Disease Diagnosis and Treatment
- Keywords
- Resovist, focal liver lesions, liver lesion characterization, hepatocellular carcinoma, hepatocellular adenoma, focal nodular hyperplasia, hepatic hemangioma, contrast-enhanced MRI
- MeSH terms
- Adult, Aged, Aged, 80 and over, Contrast Media, Dextrans, Female, Ferric Compounds, Humans, Image Processing, Computer-Assisted, Liver, Magnetic Resonance Imaging, Male, Middle Aged, ROC Curve, Reproducibility of Results, Ferrosoferric Oxide, Magnetite Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review