CoChat

Topography mapping of whole body adipose tissue using A fully automated and standardized procedure

Würslin, Christian, Machann, Jürgen, Rempp, Hansjörg, Claussen, Claus, Yang, Bin, Schick, Fritz · 2010 · Journal of Magnetic Resonance Imaging
Cited by 103

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Purpose: To obtain quantitative measures of human body fat compartments from whole body MR datasets for the risk estimation in subjects prone to metabolic diseases without the need of any user interaction or expert knowledge. Materials and Methods: Sets of axial T1‐weighted spin‐echo images of the whole body were acquired. The images were segmented using a modified fuzzy c‐means algorithm. A separation of the body into anatomic regions along the body axis was performed to define regions with visceral adipose tissue present, and to standardize the results. In abdominal image slices, the adipose tissue compartments were divided into subcutaneous and visceral compartments using an extended snake algorithm. The slice‐wise areas of different tissues were plotted along the slice position to obtain topographic fat tissue distributions. Results: Results from automatic segmentation were compared with manual segmentation. Relatively low mean deviations were obtained for the class of total tissue (4.48%) and visceral adipose tissue (3.26%). The deviation of total adipose tissue was slightly higher (8.71%). Conclusion: The proposed algorithm enables the reliable and completely automatic creation of adipose tissue distribution profiles of the whole body from multislice MR datasets, reducing whole examination and analysis time to less than half an hour. J. Magn. Reson. Imaging 2010; 31: 430–439. © 2010 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.22036

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 103

Metadata

Authors
Würslin, C., Machann, J., Rempp, H., Claussen, C., Yang, B., & Schick, F.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2010-01-23
Volume
31
Issue
2
Pages
430-439
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2014160361
Cited by
103
References
5
FWCI
7.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.