CoChat

3 Tesla and 7 Tesla MRI of multiple sclerosis cortical lesions

Open access
Tallantyre, Emma C., Morgan, Paul S., Dixon, Jennifer E., Al‐Radaideh, Ali, Brookes, Matthew J., Morris, Peter G., Evangelou, Nikos · 2010 · Journal of Magnetic Resonance Imaging
Cited by 117

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Cortical lesions are prevalent in multiple sclerosis but are poorly detected using MRI. The double inversion recovery (DIR) sequence is increasingly used to explore the clinical relevance of cortical demyelination. Here we evaluate the agreement between imaging sequences at 3 Tesla (T) and 7T for the presence and appearance of individual multiple sclerosis cortical lesions. Eleven patients with demyelinating disease and eight healthy volunteers underwent MR imaging at 3T (fluid attenuated inversion recovery [FLAIR], DIR, and T 1‐weighted magnetization prepared rapid acquisition gradient echo [MP‐RAGE] sequences) and 7T (T 1‐weighted MP‐RAGE). There was good agreement between images for the presence of mixed cortical lesions (involving both gray and white matter). However, agreement between imaging sequences was less good for purely intracortical lesions. Even after retrospective analysis, 25% of cortical lesions could only be visualized on a single MRI sequence. Several DIR hyperintensities thought to represent cortical lesions were found to correspond to signal arising from extracortical blood vessels. High‐resolution 7T imaging appeared useful for confidently classifying the location of lesions in relation to the cortical/subcortical boundary. We conclude that DIR, FLAIR, and MP‐RAGE imaging sequences appear to provide complementary information during the detection of multiple sclerosis cortical lesions. High resolution 7T imaging may facilitate anatomical localization of lesions in relation to the cortical boundary. J. Magn. Reson. Imaging 2010;32:971–977. © 2010 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.22115

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 117

Metadata

Authors
Tallantyre, E. C., Morgan, P. S., Dixon, J. E., Al‐Radaideh, A., Brookes, M. J., Morris, P. G., & Evangelou, N.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2010-09-29
Volume
32
Issue
4
Pages
971-977
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1995632570
Cited by
117
References
5
FWCI
6.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 3 Tesla and 7 Tesla MRI of multiple sclerosis cortical lesions. https://app.cochat.ai/papers/10.1002/jmri.22115
The paper
Tallantyre, E. C., Morgan, P. S., Dixon, J. E., Al‐Radaideh, A., Brookes, M. J., Morris, P. G., & Evangelou, N. (2010). 3 Tesla and 7 Tesla MRI of multiple sclerosis cortical lesions. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.22115

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.