Visualization of cerebral microbleeds with dual‐echo T2*‐weighted magnetic resonance imaging at 7.0 T
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Purpose: To assess the visualization of cerebral microbleeds with dual echo T2*‐weighted imaging at 7.0 T magnetic resonance imaging (MRI). Materials and Methods: Ten consecutive participants (eight men, two women, mean age 54 ± 12 years) with vascular disease or risk factors from the second manifestations of arterial disease (SMART) study were included. Dual‐echo T2*‐weighted scans (echo time: 2.5/15.0 msec) were made for all participants at 7.0 T MRI. The number of visible microbleeds and the diameter of the microbleeds were recorded on minimal intensity projection images of both echoes. Results: The first echo image shows dark microbleeds against a homogeneous, more hyperintense signal of the brain tissue without contrast for veins and basal ganglia. In eight patients microbleeds were observed, with a total of 104 microbleeds. Of these, 88 (84.6%) were visible on the first and 102 (98.0%) on the second echo. The mean diameter of the microbleeds was 1.24 mm for the first echo and 2.34 mm for the second echo. Conclusion: T2*‐weighted imaging at two echo times at 7.0 T combines the advantages of the first and second echo. Microbleeds visible on the first echo show large contrast with the surrounding tissue, even in the presence of paramagnetic ferritin. The second echo enables visualization of smaller microbleeds than the first echo. J. Magn. Reson. Imaging 2010;32:52–59. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cerebral microbleeds: a guide to detection and interpretation
Greenberg, S. M., Vernooij, M. W., Cordonnier, C., Viswanathan, A., Al-Shahi Salman, R., Warach, S., Launer, L. J., Van Buchem, M. A., & Breteler, M. M. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70013-4 · Cited by 1,798
Prevalence and risk factors of cerebral microbleeds: The Rotterdam Scan Study
Vernooij, M. W., van der Lugt, A., Ikram, M. A., Wielopolski, P. A., Niessen, W. J., Hofman, A., Krestin, G. P., & Breteler, M. M. B. (2008) · Neurology · doi:10.1212/01.wnl.0000307750.41970.d9 · Cited by 793
Cognitive dysfunction in patients with cerebral microbleeds on T2*-weighted gradient-echo MRI
Werring, D. J. (2004) · Brain · doi:10.1093/brain/awh253 · Cited by 421
Jeerakathil, T., Wolf, P. A., Beiser, A., Hald, J. K., Au, R., Kase, C. S., Massaro, J. M., & DeCarli, C. (2004) · Stroke · doi:10.1161/01.str.0000131809.35202.1b · Cited by 319
Prevalence and severity of microbleeds in a memory clinic setting
Cordonnier, C., van der Flier, W. M., Sluimer, J. D., Leys, D., Barkhof, F., & Scheltens, P. (2006) · Neurology · doi:10.1212/01.wnl.0000210535.20297.ae · Cited by 305
Serial Susceptibility Weighted MRI Measures Brain Iron and Microbleeds in Dementia
Kirsch, W., McAuley, G., Holshouser, B., Petersen, F., Ayaz, M., Vinters, H. V., Dickson, C., Haacke, E. M., Britt III, W., Larsen, J., et al. (2009) · Journal of Alzheimer's Disease · doi:10.3233/jad-2009-1073 · Cited by 139
Cited by
Clinical applications of 7T MRI in the brain
van der Kolk, A. G., Hendrikse, J., Zwanenburg, J. J. M., Visser, F., & Luijten, P. R. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.07.007 · Cited by 268
Self-citationIncreased Number of Microinfarcts in Alzheimer Disease at 7-T MR Imaging
van Rooden, S., Goos, J. D. C., van Opstal, A. M., Versluis, M. J., Webb, A. G., Blauw, G. J., van der Flier, W. M., Scheltens, P., Barkhof, F., van Buchem, M. A., et al. (2014) · Radiology · doi:10.1148/radiol.13130743 · Cited by 86
De Reuck, J., Auger, F., Cordonnier, C., Deramecourt, V., Durieux, N., Pasquier, F., Bordet, R., Maurage, C. A., & Leys, D. (2011) · Cerebrovascular Diseases · doi:10.1159/000324391 · Cited by 76
Metadata
- Authors
- Conijn, M. M. A., Geerlings, M. I., Luijten, P. R., Zwanenburg, J. J. M., Visser, F., Biessels, G. J., & Hendrikse, J.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2010-06-23
- Volume
- 32
- Issue
- 1
- Pages
- 52-59
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2107110361
- Cited by
- 45
- References
- 6
- FWCI
- 6.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.