Magnetic resonance imaging near metal implants
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The desire to apply magnetic resonance imaging (MRI) techniques in the vicinity of embedded metallic hardware is increasing. The soft‐tissue contrast available with MR techniques is advantageous in diagnosing complications near an increasing variety of MR‐safe metallic hardware. Near such hardware, the spatial encoding mechanisms utilized in conventional MRI methods are often severely compromised. Mitigating these encoding difficulties has been the focus of numerous research investigations over the past two decades. Such approaches include view‐angle tilting, short echo‐time projection reconstruction acquisitions, single‐point imaging, prepolarized MRI, and postprocessing image correction. Various technical advances have also enabled the recent development of two alternative approaches that have shown promising clinical potential. Here, the physical principals and proposed solutions to the problem of MRI near embedded metal are discussed. J. Magn. Reson. Imaging 2010;32:773–787. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Andersson, J. L. R., Skare, S., & Ashburner, J. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00336-7 · Cited by 3,469
Cited by
Metal-Induced Artifacts in MRI
Hargreaves, B. A., Worters, P. W., Pauly, K. B., Pauly, J. M., Koch, K. M., & Gold, G. E. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.7364 · Cited by 559
“More advanced methods as well as thorough physical explanations of the origin of susceptibility artifacts have been recently described [10].”
Self-citationJungmann, P. M., Agten, C. A., Pfirrmann, C. W., & Sutter, R. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25708 · Cited by 227
“Siemens (Erlangen, Germany) calls its dedicated MARS techniques “WARP” (conventional MARS techniques plus VAT) and “advanced WARP” (WARP plus SEMAC) (in alphabetic order).(25,69,70,72) The efficacy of these advanced metal artifact reduction techniques with respect to artifact reduction as compared to conventional sequ…”
BackgroundMethodInfluential
Metadata
- Authors
- Koch, K. M., Hargreaves, B. A., Pauly, K. B., Chen, W., Gold, G. E., & King, K. F.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2010-09-29
- Volume
- 32
- Issue
- 4
- Pages
- 773-787
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1978134131
- Cited by
- 182
- References
- 1
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic resonance imaging near metal implants. https://app.cochat.ai/papers/10.1002/jmri.22313
- The paper
- Koch, K. M., Hargreaves, B. A., Pauly, K. B., Chen, W., Gold, G. E., & King, K. F. (2010). Magnetic resonance imaging near metal implants. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.22313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.