Dual‐temporal resolution dynamic contrast‐enhanced MRI protocol for blood–brain barrier permeability measurement in enhancing multiple sclerosis lesions
Open accessThe DOI matches its Crossref record.
Abstract
Purpose: To design a more accurate and reproducible technique for the measurement of blood–brain barrier (BBB) permeability in gadolinium‐enhancing multiple sclerosis (MS) lesions. Materials and Methods: Four MS patients were scanned using a new dynamic contrast‐enhanced (DCE)‐magnetic resonance imaging (MRI) protocol based on an uninterrupted two‐part acquisition consisting of an initial part at high temporal and low spatial resolutions and a second part at low temporal and high spatial resolutions. The method preserves both the high spatial resolution needed for the often small size of lesions and the high temporal resolution required during the first minute after injection to sufficiently sample the first‐pass bolus. Simulations compared the performance of this new protocol with the conventional one at low temporal and high spatial resolutions throughout. Results: The BBB permeability estimates changed by up to 33% between the two protocols. The new protocol led to simulated error on K trans of 7%–10%, versus 7%–30% with the conventional protocol, and was more robust with respect to offsets between acquisition and injection start times, differences in shape of the first‐pass peak, and permeability values. Conclusion: The dual‐temporal resolution protocol produces improved BBB permeability estimates and provides a more complete view of active inflammatory MS lesion pathology. J. Magn. Reson. Imaging 2011;33:1291–1300. © 2011 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blood-Brain Barrier Leakage in Patients with Early Alzheimer Disease
van de Haar, H. J., Burgmans, S., Jansen, J. F. A., van Osch, M. J. P., van Buchem, M. A., Muller, M., Hofman, P. A. M., Verhey, F. R. J., & Backes, W. H. (2016) · Radiology · doi:10.1148/radiol.2016152244 · Cited by 601
Heye, A. K., Culling, R. D., Valdés Hernández, M. D. C., Thrippleton, M. J., & Wardlaw, J. M. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.09.002 · Cited by 406
Blood–brain barrier dysfunction and epilepsy: Pathophysiologic role and therapeutic approaches
Marchi, N., Granata, T., Ghosh, C., & Janigro, D. (2012) · Epilepsia · doi:10.1111/j.1528-1167.2012.03637.x · Cited by 286
Neurovascular unit impairment in early Alzheimer's disease measured with magnetic resonance imaging
van de Haar, H. J., Jansen, J. F. A., van Osch, M. J. P., van Buchem, M. A., Muller, M., Wong, S. M., Hofman, P. A. M., Burgmans, S., Verhey, F. R. J., & Backes, W. H. (2016) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2016.06.006 · Cited by 207
“The sequence described by Larsson et al. allows for measurement of the T10 with slight adaptations to the scan parameters, and it also provides an analytical formula to convert the signal changes to the contrast agent concentration.”
InfluentialCramer, S. P., & Larsson, H. B. (2014) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2014.126 · Cited by 117
van de Haar, H. J., Jansen, J. F. A., Jeukens, C. R. L. P. N., Burgmans, S., van Buchem, M. A., Muller, M., Hofman, P. A. M., Verhey, F. R. J., van Osch, M. J. P., & Backes, W. H. (2017) · Medical Physics · doi:10.1002/mp.12328 · Cited by 85
“, which was found to be more precise and less biased at estimating BBB impairment in multiple sclerosis, compared with a conventional single time resolution scan, and was also found to be relatively insensitive to variations in perfusion levels.(17) Figure 1 illustrates the time-course of the various acquisition parts…”
Method
Metadata
- Authors
- Jelescu, I. O., Leppert, I. R., Narayanan, S., Araújo, D., Arnold, D. L., & Pike, G. B.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2011-05-17
- Volume
- 33
- Issue
- 6
- Pages
- 1291-1300
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2068034417
- Cited by
- 55
- References
- 0
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.